INSTALLATION, OPERATION AND CARE OF
MEDIUM DUTY GAS CHARBROILERS
GENERAL
Gas Countertop Charbroilers are designed for commercial use only and feature fast,
efficient gas heat. Each burner is controlled by an adjustable gas valve. Cast radiants
are located directly above each burner to maintain uniform temperature. Radiants are
easily removed for cleaning when cool.
Heavy-duty, cast iron top grates are reversible to allow all or part of the cooking grid
surface to be level or sloped. Grooves, cast in the top grates, permit fat runoff and
reduce flaring when tilted towards the front. A grease drawer is provided to collect fat
run-off; it opens to the front for inspection or drain-off.
Model Number Of Burners BTU/hr Input Rating
VCRB25 / WCRB25 4 58,000
VCRB36 / WCRB36 6 87,000
VCRB47 / WCRB47 8 116,000
INSTALLATION
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the charbroiler is
found to be damaged, save the packaging material and contact the carrier within 15 days
of delivery.
Carefully unpack your charbroiler and make sure that no parts are discarded with
packaging material. A pressure regulator designed to operate with the broiler has been
supplied and must be installed before the charbroiler is placed into service (Refer to GAS
PRESSURE REGULATOR INSTALLATION in this manual).