Viking VGBQ3002T1NSS Gas Grill User Manual


 
GAS (VGSO)
Bake burner rating
• Two burners, each 20,000 BTU
(5.9 kW) Nat./LP
• Can field convert to
LP/propane (see Installation
Notes & Accessories for kit)
Fixed piping installations
o Check with local gas utility
company or with local codes
for instructions on installing
gas supply lines. All gas
connections should be made
by a competent technician
and in accordance with local
codes and or ordinances. In
the absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
o An installer-supplied gas
shut-off valve must be
installed in an easily
accessible location. All
installer-supplied parts must
conform to local codes.
o Must be isolated from the
gas supply piping system by
closing its individual manual
shut-off valve during any
pressure testing of that
system at test pressures
equal to or less than
1/2 psi (3.5 kPa).
Natural gas models
• Water column pressure
o Operating pressure—4.0”
WCP
o Supply pressure of 6” – 14”
WCP
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
• Accepts standard residential
1/2” (1.3 cm) ID gas service
line;
1/2” (1.3 cm) NPT male with
7/8” (2.2 cm) flare adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the
7/8” (2.2 cm) male flare on
the regulator assembly.
LP/propane models
• Water column pressure
o Operating pressure—10”
WCP
o Supply pressure of 11” – 14”
WCP (for fixed piping
installations)
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
• Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8" (0.95) flare adapter.
LP/propane tank installations
• Water column pressure
o Operating pressure—10”
WCP
• Includes high-capacity
hose/regulator assembly for
connection to a standard
5-gal./20-lb. (approx.
12” diameter/18"H.)
LP/propane gas cylinder
equipped with a Type 1, QCC-
1 connector
o The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
o The cylinder must be
provided with a shut-off
valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified.
o The cylinder supply system
must be arranged for vapor
withdrawal and provided
with a listed OPD (overfilling
prevention device).
ELECTRICAL
Smoker element rating
• One element 300 watts (2.7
amps)
Cook element rating
• Two (elements, each 750 watts
(6.8 amps)
VEOS
o 120V/60 Hz, 30-amp
o 4’ (121.9 cm) 3-wire cord
with grounded 3-prong plug
o Max. amp usage—17.7
(1,950 watts)
VGSO
o 9-volt battery for ignition
PLUMBING
Not applicable
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM 1-888-VIKING1
REVISED 1/28/09
©2009 VRC—INFORMATIONSUBJECT TOCHANGE
OUTDOOR—COOKING
Built-In 30”W. Electric Smoker Oven & 26”W. Gas Oven
UTILITY
REQUIREMENTS
Installation Requirements
VEOS100T
30”W. Electric
Smoker Oven
VGSO260T
26”W. Gas Oven