Viking VGBQ Gas Grill User Manual


 
VGBQ530-4RE1
T-Series/E-Series
Four-Burner All-Grill
VGBQ532-3RE1
T-Series/E-Series
Three-Burner Grill
w/Side Burners
VGIQ530-4RT/E1
T-Series/E-Series
Four-Burner All-Grill
(inc. TruSear™ Burner)
VGIQ532-3RT/E1
T-Series/E-Series
Three-Burner Grill
w/Side Burners
(inc. TruSear™ Burner)
GAS
Fixed piping installations
Check with local gas utility
company or with local codes
for instructions on installing gas
supply lines. All gas
connections should be made
by a competent technician and
in accordance with local codes
and or ordinances. In the
absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
An installer-supplied gas shut-
off valve must be installed in an
easily accessible location. All
installer-supplied parts must
conform to local codes.
Must be isolated from the gas
supply piping system by closing
its individual manual shut-off
valve during any pressure
testing of that system at test
pressures equal to or less than
1/2 psi (3.5 kPa).
Natural gas models
Water column pressure
o Operating pressure—4.0”
WCP
o Supply pressure of 6” – 14”
WCP
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.
LP/propane models
Water column pressure
o Operating pressure—10”
WCP
o Supply pressure of 11” – 14”
WCP (for fixed piping
installations)
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.
LP/propane tank installations
Water column pressure
o Operating pressure—10”
WCP
Includes high-capacity
hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector
o The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.
o The cylinder must be
provided with a shut-off valve
terminating in an LP/propane
gas supply cylinder valve
outlet specified.
o The cylinder supply system
must be arranged for vapor
withdrawal and provided with
a listed OPD (overfilling
prevention device).
ELECTRICAL
T-Series models
o 9-volt DC battery for
electronic ignition (not
included?)
o 2’ (61.0 cm) power cord
supply cord with 3-prong
grounded plug attached to
rotisserie
120 VAC/60 Hz
o Rotisserie motor max. amp
usage—6.0
E-Series models
o 3’ (91.4 cm) power cord
supply cord with 3-prong
grounded plug attached to
grill
120 VAC/60 Hz
o Grill max. amp usage—3.0
o 2’ (61.0 cm) power cord
supply cord with 3-prong
grounded plug attached to
rotisserie
120 VAC/60 Hz
o Rotisserie motor max. amp
usage—6.0
PLUMBING
Not applicable
PLANNING AND DESIGN GUIDE
VIKINGRA NGE.COM 1-88 8-VIKI NG1
OUTDOOR—COOKING
53”W. Ultra-Premium T-Series/E-Series Gas Grill
UTILITY
REQUIREMENTS
Installation Requirements
VGBQ530-4RE1 VGBQ532-3RE1 VGIQ530-4RT/E1 VGIQ532-3RT/E1
Burner rating
Standard SS grill burners (each)
25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP (T-Series)
29,000 BTU (7.3 kW) Nat./28,000 BTU (6.5 kW) LP (E-Series)
Smoker burner (split standard) 12,500 BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP
GourmetGlo™ rotisserie burner 15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
Side grill burners (each) 15,000 BTU (4.4 kW) Nat./ 15,000 BTU (4.4 kW) Nat./
13,500 BTU (4.0 kW) LP 13,500 BTU (4.0 kW) LP
TruSear infrared burner
3
0,000 BTU (8.8 kW) Nat./LP
3
0,000 BTU (8.8 kW) Nat./LP
RELEASED 8/5/08