Royal Consumer Information Products Gas Fire Fire Pit User Manual


 
INSTALLATION INSTRUCTIONS
THE FOLLOWING SECTION LISTS THE INSTALLATION REQUIREMENTS AND REGULATIONS
A competent person in accordance with the current Gas Safety (Installation and Use) Regulations or the rules in force and
in accordance with the manufacturers instructions must install the appliance; failure to do so could lead to prosecution.
The following are the relevant Codes of Practice and British Standards.
The Building Regulations issued by the Department of the Environment. The Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
BS 8303 Pt 2 1994 BS 5440 Pt. 1 1990 & Pt. 2 1989
BS 1251 1987 BS 5871 Pt. 2 1991 & Pt. 3 1991
BS 6891 1988 BS 6461 Pt. 1 1984
BS 715 1993 BS 1289 Pt. 1 1986
BS 7566 Pts. 1-4 1992
Technical Data
Overall height of fire with spacer = 612mm
Overall height of fire without spacer = 605mm
Minimum height of opening required = 540mm
Maximum height of opening with spacer = 590mm
Maximum width of opening required = 405mm
Maximum width of opening with spacer = 470mm
Forward projection from opening = 60mm
(without front and fret)
Forward projection from opening with = 105mm
spacer (without front and fret)
Depth behind opening without spacer = 190mm
Depth behind opening with spacer = 145mm
(See page 18 for diagram)
TYPE OF GAS G20 only
Supply Pressure 20 mbar +/- 1 mbar (Cold)
GAS INPUTS
Max 6.6 kW (22520 Btu/h)
Min 3.6 kW (12300 Btu/h)
Pilot 0.26 kW (890 Btu/h)
Main Injector Type
Stereomatic 046/19/196/74M
Gas valve Concentric TESA 3058/S
Pilot OP Oxy-Pilot NG 9022
GAS CONNECTION 8MM OD Tube
WEIGHT
12.5 kg (without front and fret)
Page 4