Rinnai 4500 Outdoor Fireplace User Manual


 
16 Rinnai Corporation ROF4500
Installing Body Assembly in an Open 1-Sided or 2-Sided Installation
Angled Clearance
Brackets
Designed to ensure combustible framing is greater than 1 inch (25 mm) from the sides of
the unit as shown.
Top View
Open 1-sided
Cabinet
Top View
Open 2-sided
Cabinet
To install:
1. Measure the distance between studs to ensure clearances are adequate, horizon-
tally and vertically.
2. Screw clearance brackets to the inner side of stud.
3. Ensure that the flat face of the clearance bracket is facing out as shown above.
Clad Surround
Refer to the section, Guidelines for Cladding and Finishes.
48.3 in (1225 mm) minimum
cabinet
non combustible
cladding
clearance
bracket
timber stud
46.5 in (1180 mm) minimum
47.0 in (1195 mm) maximum
19.7 in
(500 mm)
minimum
48.3 in (1225 mm) minimum
non combustible
cladding
clearance
bracket
timber stud
46.5 in (1180 mm) minimum
47.0 in (1195 mm) maximum
18.5 in
(470 mm)
minimum
cabinet