C. Gas Connection
Note: Havethegassupplylineinstalledin accordance
with local building codes, if any.If not,followANSI
223.1.Installationshouldbedonebyaqualiedinstaller
approvedand/orlicensedasrequiredbythelocality.(In
theCommonwealthofMassachusettsinstallationmustbe
performedbyalicensedplumberorgastter.)
Note: A listed(andCommonwealthofMassachusetts
approved)1/2in.(13mm)T-handlemanualshut-offvalve
andexiblegas connectorareconnected tothe1/2in.
(13mm)controlvalveinlet.
If substituting for these components, please consult
local codes for compliance.
WARNING
Fire Risk
Explosion Risk
• Gasbuild-up during linepurge may
ignite.
• Purgeshouldbeperformedbyqualied
technician.
• Ensureadequateventilation.
Ensure there are no ignition sources such
assparksoropenames.
• Incominggas line shouldbe pipedtothe1/2 in.
connection.
• Theapplianceanditsindividualshutoffvalvemustbe
disconnectedfromthegassupplypipingsystemduring
anypressuretestingofthatsystemattestpressures
inexcessof1/2psi(3.5kPa).
• Asmallamountofairwillbeinthegassupplylines.
Whenrstlightingapplianceitwilltakeashorttime
forairtopurgefromlines.Subsequentlightingofthe
logsetwillnotrequiresuchpurging.
WARNING
CHECK FOR GAS LEAKS
Fire Risk
Explosion Risk
Asphyxiation Risk
• Checkallttingsandconnections.
• Donotuseopename.
• Afterthegaslineinstallationiscomplete,
allconnectionsmustbetightenedand
checkedforleakswithacommercially
available,non-corrosive leakcheck
solution.Besuretorinseoffallleakcheck
solutionfollowingtesting.
Fittingsandconnectionsmayhaveloosened
duringshippingandhandling.
D. High Altitude Installations
OMNIgasappliancesaretestedandapprovedwithoutre-
quiringchangesforelevationsfrom0to2000ftintheUSA
andCanada.
Wheninstallingthisapplianceatanelevationabove2000ft,
itmaybenecessarytodecreasetheinputratingbychang-
ingtheexistingburneroricetoasmallersize.Inputrate
shouldbereducedby4%foreach1000ftabovea2000ft
elevationintheU.S.A.,or10%forelevationsbetween2000
and4500ftinCanada.Iftheheatingvalueofthegashas
beenreduced,theserulesdonotapply.Toidentifytheprop-
eroricesize,checkwiththelocalgasutility.
Ifinstallingthisapplianceatanelevationabove4500ft(in
Canada),checkwithlocalauthorities.