DAMPER STOP INSTALLATION
The damper must be permanately locked in position to
prevent full closure and to provide a minimum flue opening.
Various methods for locking the damper may be used but
may be restricted from region to region and it is important
to know the specifics that apply to your area. For your
convenience a damper stop is provided with the unit and
may be used where not prohibited by state or local codes.
Use the 3” adjustable bolt to adjust the damper to the correct
opening, based on the enclosed chart.
Should the damper stop not fit, or provide the required per-
manent opening from the Minimum Damper Opening ta-
ble, have the damper cut to provide a minimum permanent
opening or install an alternate stop.
GNINEPOREPMADMUMINIM
)sehcnierauqs(
yenmihC
thgieH
yrnosaM
ecalperiF
tliuByrotcaF
ecalperiF
6
"8.33
8
"2.13
01
"7.82"1.22
51
"1.62"3.71
02
"7.32"5.41
52
"7.22"6.21
03
"6.12"3.11
53
"8.01
04
"2.0
1
Creosote, ashes and loose paint must be cleaned from
the chimney flue and firebox by a qualified chimney
cleaner, before installing in a solid fuel burning fireplace.
Any outside air ducts and/or ash dumps in the fireplace
shall be permanently closed at time of appliance
installation.
INSTALLING IN A VENTED APPLICATION
Unvented gas heaters are a supplemental zone
heater. They are not intended to be the primary
heating appliance.
Unvented gas heaters emit moisture into the
living area. In most homes of average construc-
tion, this does not pose a problem. In houses of
extremely tight construction, additional me-
chanical ventilation is recommended.
During manufacturing, fabricating and shipping
various components of this appliance are
treated with certain oils, films or bonding
agents.
These materials may produce smoke and smells
as they are burned off during the initial
operation of the appliance; possibly causing
headaches or eye or lung irritation. This is a
normal and temporary occurance. Simply open a
window to ventilate the room during the burn off