Gas Line Installation
Thisappliancemustbeisolatedfromthegassupply
pipingsystembyclosingitsindividualmanualshutoff
valveduringanypressureequaltoorlessthan1/2psig
(3.45kPa).
Theapplianceanditsindividualshutoffvalvemustbe
disconnectedfromthegassupplypipingsystemduring
anypressuretestingofthatsystemattestpressuresin
excessof1/2psig(3.45kPa).
Ifgaspipingfromthesourcetotheappliancelocation
hasnotbeenaccomplished,installtherequiredpipe.
Consultlocalplumbingcodetoassureproperpipesize.
Thegaspipelinecanbebroughtinthroughtheright
sideoftheappliance.Aknockoutisprovidedtoallow
forthegaspipeinstallationandtestingofanygascon-
nection.
NOTE: Thegaslineconnectioncanbemadewith3/8"
coppertubingapprovedforpropaneornaturalgas,1/2"
rigidpipeoranapprovedflexconnector,thenreduced
to3/8"totheappliance.Becausesomemunicipalities
havesomeadditionallocalcodes,itisalwaysbestto
consultyourlocalauthority.
U.S.:ConsultthecurrentNationalFuelGasCode,ANSI
Z223.1/NFPA54.
Canada:CSA-B149.1installationcode.
Testforleaks.Usea50/50solutionofliquidsoapand
watertotestforleaksatgasfittingsandjoints.Apply
water/soapsolutionwithbrushonly-donotoverapply.
NEVER testwithanopenflame.
Thegascontrolisequippedwithacapturedscrewtype
pressuretestpoint,thereforeitisnotnecessarytopro-
videa1/8"testpointupstreamofthecontrol.
Whenusingcopperorflexconnectoruseonlyapproved
fittings.Always provide a unionsothatgaslinecan
beeasilydisconnectedforburnerorfanservicing.
Seegasspecificationforpressuredetailsandratings.
NOTE:Ifflexconnectorisused,itmustbekeptinside
oftheappliance.(Fig.10)
FP598
Fig. 10 Typicalgassupplyinstallation.
GF598
nvb GAS SUPPLY INSTALL
12/4/97
1/2"GasSupply
1/2"x3/8"Shut-offValve
3/8"Nipple
3/8"Union
3/8"Nipple