7
ODGR Series Outdoor Gas Fireplace
92D0001
Gas Inlet & Manifold Pressures
Natural LP
MinimumInletPressure 5.5”w.c. 11.0”w.c.
MaximumInletPressure 14.0”w.c. 14.0”w.c.
ManifoldPressure 3.5”w.c. 10.0”w.c.
Gas Specification
Max. Min.
Model Fuel Gas Control Input Input
ODGR400NV Nat. MillivoltHi/Lo 60,000 42,600
ODGR400PV Prop. MillivoltHi/Lo 60,000 44,000
ODGR500NV Nat. MillivoltHi/Lo 60,000 42,600
ODGR500PV Prop. MillivoltHi/Lo 60,000 44,000
High Elevations
Input ratings are shown in BTU per hour and are
certified without deration from elevations up to
4,500 feet (1,370 m) above sea level.
Nuisance outages may occur at altitudes above
4,500 feet (1,370 m) if dirt, dust, lint and/or cob-
webs are allowed to accumulate on burner and/or
ODS pilot. Monthly inspection and cleaning is rec-
ommended for altitudes above 4,500 feet (1,370 m)
For elevations above 4,500 feet (1,370 m), instal-
lations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having
jurisdiction.
Valve Access
Valveaccesscanbeaccomplishedinoneoftwoways:
1. Removethefrontpaneljustbelowthefrontofthe
hearthpan.Thisisaccomplishedbyliftingonthe
panel.Toreplacethevalveaccesspanellineupthe
twopinswiththeholesinthesurroundbottomand
pushthepaneloverthefrontofthehearthpan.(Fig.
5)
2. Liftthebrickwiththelogoonit.(Fig.6)
ODGR400 / ODGR500
Certified to
CSA 4-96
FP1414
ODUVSR
valve access
11/24/03 djt
FP1414
Fig. 5Valveaccess.
FP1415
lift brick access
11/24/03 djt
LogoBrick
Fig. 6Liftbrickwithlogoonittoaccessvalve.
FP1415
1/2” (13 mm)
FP1642a
concrete install
9/06
NOTE:Wheninstallationis
onahard,flatsurface(such
asconcrete),thesurface
mustbesloped1/4"perfoot
awayfromanystructure.
Blocking
Hard,FlatSurface
(i.e.concrete)
FP1642a