Majestic Appliances ODGSR36APAU Outdoor Fireplace User Manual


 
Figure 3
Finishing
CAUTION: All joints between the finished wall and the appliance surround
(top and sides) may be sealed only with a non-combustible material. Only
non-combustible material can be applied as facing to the appliance surround
as per Figures 2a and 2b.
Gas Specification (always refer to appliance Data plate)
GAS SPECIFICATION
MODEL GAS TYPE GAS
CONTROL
Max Input
MJ/h
Min Input
MJ/h
ODGSR36ANAU Nat Millivolt Hi/Lo 60 43
ODGSR36APAU Propane Millivolt Hi/Lo 60 44
GAS INLET AND MANIFOLD PRESSURE kPa
NATURAL PROPANE
Min Supply Pressure 1.13 2.75
Max Supply Pressure 3.50 3.50
Burner Test point
Pressure
0.80 2.50
The gas control valve has test point connections for both inlet and burner test point
(outlet) pressures, integral with the valve.
Page 9 of 18