Maintenance
The appliance should be thoroughly inspected
before initial use and at least annually by a
qualified service technician. However, more
frequent periodic inspections and cleanings
should be performed by the homeowner.
Homeowner must contact a qualified service
technician at once if any abnormal condition
is observed.
Refer to the maintenance schedule for main-
tenance tasks, procedures, periodicity and
by whom they should be performed. Always
verify proper operation of the appliance after
servicing.
IMPORTANT: TURN OFF GAS AND ANY
ELECTRICAL POWER BEFORE SERVICING
THE APPLIANCE.
Battery Replacement
The intermittent ignition system operates on 3
volts provided by two (2) "D" cell batteries. The
batteries are located in a pack installed within
the J-Box, behind the stainless ON/OFF switch
panel. Refer to Figure 3.
Note: All batteries loose voltage when frozen
or left for prolonged periods. It may be wise
to remove batteries during extended periods
of disuse.
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled by a
remotely located wall switch.
Gas Controls/Control Compartment Access
The gas controls can be found beneath the bot-
tom refractory. Remove the bottom refractory
by lifting it up. Remove the access cover (refer
to Figure 1 ).
All Models -
To light these appliances refer to the detailed
lighting instructions found in both English and
French on pages 14 and 15 of these instructions
respectively. The appliance lighting instruc-
tions may also be found on the pull out lighting
instruction labels attached to the gas control
valve. See Figure 1 for its location.
Variable Flame Height Adjustment
1. All appliances are equipped with a variable
gas control valve. Flame height for these models
may be adjusted through a range between fixed
low and high settings, alternately, while the
appliance is in operation.
Adjust the flame height as desired after lighting
the appliance by rotating the variable adjustment
control knob located on the front of the valve
(see Figure 2).
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is due
to the “burn-in” of internal paints and lubricants
used in the manufacturing process.
3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materials,
etc. It is important that control compartments,
burners and circulating air passageways of the
appliance be kept clean.
4. Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable liquids.
Switch
Cover
Weather Seal
Orient Batteries Vertically
To Fit Within Box
Pilot Stage
Terminal
Pressure-Tap
(Inlet)
Pilot Gas
Outlet
Supply
Gas
Inlet
Pressure-Tap
(Manifold)
Burner Stage
Terminal
Ground
(TP)
PILOT
OUT
VENT
LO
TH
TP
TH
TP
HI
IN
IN
Gas Outlet
To Burner
Regulator
Mounting Screw
Figure 3 Battery Replacement