6. On some models, install rotisserie mounting bracket using
2 screws.
7. Dispose of/recycle all packaging material.
Make Gas Connection
NOTE: If grill has been converted to LP gas, follow instructions in
“Conversion to LP Gas” at the end of this section.
Natural Gas Use
The installation of this grill must conform with local codes or, in
the absence of local codes, with either the National Fuel Gas
Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane
Installation Code, CSA B149.1, or Propane Storage and Handling
Code, B149.2.
1. Place grill into outdoor enclosure, but leave enough room in
back to connect to gas supply and electrical plug-in.
2. Make gas connections.
A combination of pipe fittings must be used to connect the
grill to the existing gas line.
■ If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified by CSA
International, to connect the grill to the rigid gas supply
line. A ⁵⁄₈" diameter line is recommended. Using a wrench
to tighten, connect the gas supply to the grill. Use pipe-
joint compound on all non-flared male threads. Do not
kink or damage the flexible connector when moving the
grill.
■ Pipe-joint compounds suitable for use with Natural gas
must be used. Do not use Teflon
®
tape.
3. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
Plug in Grill
1. This built-in outdoor grill comes with a 5,000 mAmp power
transformer plug assembly for the grill lights and igniter. Plug
in the single-prong plug in the receptacle on the left
underside of the grill.
A. 2 screws
B.Rotisserie bracket
A B
WARNING
Fire Hazard
Do not use grill near combustible materials.
Do not store combustible materials near grill.
Doing so can result in death or fire.
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
Failure to do so can result in death, explosion, or fire.
A. Grill gas pipe
B.New CSA International approved
“outdoor” flexible gas supply line
C. Rear of grill
D. To Natural gas supply
A. Closed valve
B. Open valve
A. Single-prong plug
A
B
C
D
A
B