TO CONVERT APPLIANCE FOR USE WITH NATURAL GAS
PROPANE GAS (LP) -- TO m NATURAL GAS CONVERSION INSTRUCTIONS
If this appliance has been converted for use with LP gas, each of the following modifications must be
_erformed to convert the unit back to Natural Gas.
WARNING
Natural Gas conversion is to be performed by a JENN-AIR AUTHORIZED SERVICE
CONTRACTOR (or other qualified agency) in accordance with the manufacturer's instructions
and all codes and requirements of the authority having jurisdiction. Failure to follow instructions
could result in serious injury or property damage. The qualified agency performing this work
assumes responsibility for this conversion.
I WARNING
ELECTRICAL POWER AND GAS MUST BE TURNED OFF PRIOR TO CONVERSION.
Manifold -- Natural Gas pressure required ............................................................................ 5" W.C.
Incoming Natural Gas pressure required to appliance pressure regulator ....................... 6" - 7" W.C.
MODEL CVG4200, CVG4280 SERIES
o &oLT ,RROA.CEPRESSOREREGO 'TOR
BLOWERCAN BE "_"--WIRING BOX
COVER
GREASE
CONTAINER
A. Replace all orifice hoods - Performsteps1 through4on page 4. Locatethe (4) four or (2)twoNaturalGas hoods(with
smallnumbersstampedontheirsides)savedfromthe originalNaturalGasunit.Page4 illustration"E".Thetwo hoods
with.0520(#55 orifice)stampedonthemarefortheleftfrontandleft rearburners.Thetwo hoodswiththe.0595 (#53
orifice)stampedonthem are forthetworightburners.
To maketheseconversionadjustmentsfollowthe instructionsandillustrations("A" through"E") pages3and 4.
B. Invertcapin appliancepressureregulator(seeillustration"D"). Withtheapplianceinstalled,theappliancepressure
regulatorislocatedonthecenterunderside(doublebay)andrightunderside(singlebay)ofthe applianceat the inletto
thegasmanifold.Identifythetypeof appliancepressureregulatorontheunitandfollowtheinstructionsintheappropriate
illustration.
C. Adjust low flame setting for each burner, Followthe instructionsfor burnerlowflame adjustmenton page 4 to
increasethesimmerflamesize.
NaturalGasinputspecified,ModelCVG4200,CVG4280(Double)Series..................................................36,000 BTU/hr.
'_turalGasinputspecified,ModelCVG4100 (Single)Series.....................................................................16,000BTU/hr.
,.eft rearburner(LR)-- 8,000 BTU/hr.-- #55 orifice-- .0520 inchesdia.(GreenColor)See sketch,page6.
Left.frontburner(LF)-- 8,000 BTU/hr.-- #55orifice-- .0520inchesdia.(GreenColor)Seesketch,page6.
Rightrearburner(RR)-- 10,000BTU/hr.-- #53 orifice-- .0595inchesdia.(BrassColor)
Rightfrontburner(RF) -- 10,000BTU/hr.--#53 orifice-- .0595 inchesdia. (BrassColor)
7