Heat & Glo LifeStyle PCFM-HNG Outdoor Fireplace User Manual


 
4 Heat & Glo LifeStyle Collection • Patio Camp re • Rev B • 08/08
1
1
Listing and Code Approvals
A. Appliance Certi cation
The Patio Camp re has been tested in accordance with
IAS US requirements for Outdoor Gas Fireplaces,
Draft 4-96 and ANSI Z21.58-1995/CGA 1.6-M96 for Cana-
da and has been listed by Underwriters Laboratory (UL) for
installation and operation as described in these installation
and operating instructions.
The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code
ANSI Z223.1 or CAN/CGA-B149.1, National Gas Instal-
lation Code or CAN/CGA-B149.2, Propane Installation
Code.
MODELS: PCFM-HNG, PCFML-HNG
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Decorative Gas Log Set
STANDARD: IAS US requirements for Outdoor
Gas Fireplaces, Draft 4-96 and ANSI Z21.58-1995/
CGA 1.6 M96
B. BTU Speci cations
C. High Altitude Installations
U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2000 feet in the
U.S.A. and Canada.
When installing this appliance at an elevation above 2000 ft,
it may be necessary to decrease the input rating by chang-
ing the existing burner ori ce to a smaller size. Input rate
should be reduced by 4% for each 1000 ft above a 2000 ft
elevation in the U.S.A., or 10% for elevations between 2000
and 4500 ft in Canada. If the heating value of the gas has
been reduced, these rules do not apply. To identify the prop-
er ori ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 ft (in
Canada), check with local authorities.
Model
Max Input
BTUH Ori ce Size
PCFM-HNG 75,000 #27/.144
PCFML-HNG 60,000 #44/.086