Part # JIBSM08 Rev 7 (08/04/09)Page 38
Controller Displays “FAULTY ELEMENT OR SHORTED PROBE” -
Only 1 or 2 zones LED lights are RED
NO
YE S
YES
YE S
YE S
YE S
NO
NO
NO
NO
NO
NO
NO
NO
Check for 3-phase
voltage at primary
side of main contactors
Check to ensure that 3-phase
power cords are securely
fastened and plugged
into their receptacles
Fasten & plug in 3 phase
power cords
Check for 3-phase
voltage at secondary
side contactor
Ensure that main 3-phase circuite
breakers are not tripped
or turned o
Check for Soild State Relay
Closure by measuring
approx 0 VAC on output
Replace eected
Solid State Relay
Replace Bad Contactor
Check for disconnected or
damaged molex plugs
going to heating elements
Check for full line voltage
at eected heating element
Replace heating element
Check for a full amperage
draw on eected element
Check for approx. 8.9 VDC
at input side of eected
heat zone’s Solid State Relay
Check for loose pins or damaged
wires from Controller routed
to eected zone’s
Solid State Relay
Replace Main Controller
TECHNICAL TROUBLESHOOTING continued