Garland XG24-JIB Gas Grill User Manual


 
Part # JIBSM08 Rev 7 (08/04/09)Page 38
Controller Displays “FAULTY ELEMENT OR SHORTED PROBE” -
Only 1 or 2 zones LED lights are RED
NO
YE S
YES
YE S
YE S
YE S
NO
NO
NO
NO
NO
NO
NO
NO
Check for 3-phase
voltage at primary
side of main contactors
Check to ensure that 3-phase
power cords are securely
fastened and plugged
into their receptacles
Fasten & plug in 3 phase
power cords
Check for 3-phase
voltage at secondary
side contactor
Ensure that main 3-phase circuite
breakers are not tripped
or turned o
Check for Soild State Relay
Closure by measuring
approx 0 VAC on output
Replace eected
Solid State Relay
Replace Bad Contactor
Check for disconnected or
damaged molex plugs
going to heating elements
Check for full line voltage
at eected heating element
Replace heating element
Check for a full amperage
draw on eected element
Check for approx. 8.9 VDC
at input side of eected
heat zone’s Solid State Relay
Check for loose pins or damaged
wires from Controller routed
to eected zone’s
Solid State Relay
Replace Main Controller
TECHNICAL TROUBLESHOOTING continued