Enviro 828 DV.INS. Fire Pit User Manual


 
2. Place the log with Burnt Area forward on log
supports. Locate the log by matching the bottom
pegs to the receiving holes in rear log supports.
3. Close door securely
7. ELECTRICAL REQUIREMENTS
The ENVIROGAS 828 Series will operate without an external electrical power supply. This model has a Millivolt gas control
which uses the pilot flame to generate enough electricity to operate the main burners.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.
FAN INSTALLATION
OPTIONAL FAN
Efficiency and heat output of the unit increases with the operation of the fan.
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard, and should be
plugged directly into a properly grounded three-prong outlet. DO NOT cut or remove the grounding prong from this plug.
The appliance, when installed with optional blower , must be electrically connected and grounded in accordance with local
codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY
STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.
9