Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
36J22, 36J24, 36J54 and 36J55
DSI and HSI Single and Two Stage
Combination Gas Valves
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
The 36J22/24/54/55 combination gas valves are de-
signed for direct spark ignition (DSI) and hot surface
ignition (HSI) system applications. These valves
are equipped with redundant and main solenoid
valves that control gas ow to the main burners, a
pressure regulator and a two-position on/o switch
for regulation and electrical shut-o of the solenoid
valves. The 36J24 and 36J55 are also equipped
with a slow-opening pressure regulator for softer
lighting characteristics. When the second solenoid
on 2-stage valves is energized the valve operates
at the second stage (high) outlet pressure setting.
Type of Gas: Natural gas
LP gas (use conversion kit)
Ambient Temperature: -40° to 175°F
Pressure Rating: 14" W.C. (½ PSI) max.
Voltage: 24 VAC
Frequency: 50/60 Hz
Current: Single Stage – 0.28A
Two-Stage – 0.43A
Mounting Positions: Multipoise – Control may
be mounted in any position
CONTENTS
Description ........................................................ 1
Specications .................................................... 1
Precautions ....................................................... 2
Installation
System Wiring ...................................... 3
Adjustment
Pressure Regulator Adjustment ............ 6
Lighting Instructions .......................................... 8
Contents French ................................................ 9
Contents Spanish ............................................ 17
36J Two-Stage
36J Single Stage
PIPE SIZES/CAPACITIES
Pipe Sizes
Available
(inches)
1
/2" x
1
/2" NPT 140,000
AGA Std. Nat. Gas
(1,000 BTU/cu. ft.)
226,800
LP Gas
(2,500 BTU/cu. ft.)
Capacity (BTU/hr) at
1” pressure drop across valve
Fig. 1
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
SPECIFICATIONS
DESCRIPTION
PART NO. 37-7338A
1224
www.white-rodgers.com
www.emersonclimate.com
Model
Number
Coil
Voltage
Stages
Opening
Characteristics
Intermittent Pilot
Proven Pilot
HSI DSI
Standing
Pilot
36J22 24V 1 Fast No Yes Yes No
36J24 24V 1 Slow No Yes Yes No
36J54 24V 2 Fast No Yes Yes No
36J55 24V 2 Slow No Yes Yes No
Pressure Regulator Adjustment Range (in W.C.)
Two Stage
Gas
Type
Single
Stage
Low High
Min. Di.
Low to High
Natural 2.5 – 5.0 1.0 – 4.0 2.0 – 5.0 1
LP 7.0 – 12.0 4.0 – 10.0 6.0 – 12.0 2