Desa VSGF33PRC Outdoor Fireplace User Manual


 
www.desatech.com
119304-01A20
2. Thereceivercontinuouslyreceivessignals
from the hand-held remote to control the
room temperature. If the hand-held remote
ismisplaced,obstructed,orforanyreason
cannottransmittothereceiver,thereceiver
willshutoffthereplaceafter8minutes.

This feature allows the user to lock/unlock
the keypad on the hand-held remote in the
MANUorAUTOmodetopreventinadvertent
operation(i.e.childrenoperatingthehand-held
remotecontrol,etc.).Thekeypadislockedin
eitheronoroff.PressthePOWERandLOCK
buttonstogethertoturntheunitonoroff.





-




Locatetheblowerswitchbyopeninglower
louveronreplace.Blowerswitchislocatedat
lower left inside louver door.
TheGA3650TBthermostat-controlledblower
hasavariablespeedcontrolwithanON/OFF
switch. The blower will start when the ther-
mostatsensesasufcientincreaseinrebox
temperature.TheGA3750Avariablespeed
bloweralsohasanON/OFFswitchbuiltinto
the variable speed control.
 Ifyouareusing
GA3650TBblower,yourreplaceandblower
will not turn on and off at the same time. The
replacemayrunforseveralminutesbeforethe
blower turns on. After the heater modulates to
thepilotposition,theblowerwillcontinueto
run.Theblowerwillshutoffaftertherebox
temperature decreases.
Note:Itissafetooperatereplacewithblower
turnedoff.However,theblowerhelpsdistribute
heatedairfromthereplace.
Follow installation instructions included with
the blower accessory.
OPERATING FIREPLACE
Continued
INSPECTING BURNERS
Check pilot ame pattern and burner ame pat-
terns often.

Figure 32 shows a correct pilot ame pattern.
Figure 33 shows an incorrect pilot ame pattern.
The incorrect pilot ame is not properly heating
the thermocouple. When the thermocouple cools,
the heater will shut down.
If pilot ame pattern is incorrect, as shown in
Figure 33
turn heater off (see To Turn Off Gas to Appli-
ance, page 18)
see Troubleshooting, page 23
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be blue and
have no yellow or orange color.
Figure 33 - Correct Pilot Flame Pattern
Figure 34 - Incorrect Pilot Flame Pattern
Pilot Burner
Thermocouple
Thermocouple
Pilot Burner

Periodically inspect all burner ame holes with
the heater running. All slotted burner ame holes
should be open with yellow ame present. All
round burner ame holes should be open with a
small blue ame present. Some burner ame holes
may become blocked by debris or rust, with no
ame present. If so, turn off heater and let cool.
Remove blockage. Blocked burner ame holes
may create soot.

   
-
-

  
    
