INSTALLATION
Continued
We recommend that you install a sediment trap in
supply line as shown in Figure 20, page 16. Locate
sediment trap where it is within reach for cleaning.
Install in piping system between fuel supply and
heater. Locate sediment trap where trapped mat-
ter is not likely to freeze. A sediment trap traps
moisture and contaminants. This keeps them from
going into replace controls. If sediment trap is
not installed or is installed wrong, replace may
not run properly.


CONTROL
Installation Items Needed
Phillips screwdriver
sealant (resistant to propane/LP gas, not
provided)
1. Open lower louver (see Figure 21).
   
    

is provided to allow accessibility

-
nection to the equipment shutoff

2. Route exible gas line, included, from re-
place control to equipment shutoff valve
through side access holes in outer casing.
3. Apply pipe joint sealant lightly to male threads
of gas connector attached to exible gas line/
equipment shutoff valve (see Figure 22).



   -


    
   
   

Figure 21 - Flexible Gas Line Location
(Remote-Ready Unit Shown)
O
F
F
P
I
L
O
T
O
N
H
I
L
O
Lower
Louver
Flexible Gas
Line
Figure 22 - Attaching Flexible Gas Line
to Equipment Shutoff Valve
Flexible Gas Line
from Fireplace
Gas Regulator
Provided With
Fireplace
To Gas Regulator (Thermostat-
Controlled Models) or Control
Valve (Remote-Ready Models)
Equipment
Shutoff
Valve

To External Regulator
NATURAL GAS
To Gas Supply


and connections, internal and
external to unit, for leaks after


WARNING: Never use an

Apply a noncorrosive leak detec-



4. Check all gas connections for leaks. See
Checking Gas Connections, below. Feed
exible gas line into replace. Make sure the
entire exible gas line is in replace.