Desa LMFP33PR(A) Outdoor Fireplace User Manual


 
www.desatech.com
111604-01L 9
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top Left and Bottom
Right Sides and Rear
42" 16" 0"
Figure 5 - Installing Hood to Firebox
Figure 6 - Assembling Trim
Side Trim
Slot
Mitered
Edge
Slot
Shim
Set Screws
Adjusting
Plate
Trim
Hanging
Screws
Assembled
Trim
Hanging
Notches
on Trim
INSTALLING HOOD
Install hood to top of firebox as shown in Figure
5. Use 3 Phillips screws provided
Top Trim
INSTALLATION
Continued
Figure 7 - Attaching Trim to Fireplace
*
Example
Figure 8 - Minimum Clearance for
Combustible to Wall
*Minimum 16 inches from Side Wall
ASSEMBLING AND ATTACHING
OPTIONAL TRIM
(Included with Mantel Accessory)
IMPORTANT: If you are recessing the firebox in a
wall, do not attach trim at this time. See page 11.
Note: The instructions below show assembling
and attaching trim to fireplace.
1. Remove packaging from three pieces of trim.
2. Locate four brass screws, two adjusting plates
with set screws and two shims in the hardware
packet.
3. Align shim under adjusting plate as shown in
Figure 6.
4. Slide one end of adjusting plate/shim in slot
on mitered edge of top trim (see Figure 6).
5. Slide other end of adjusting plate/shim in slot
on mitered edge of side trim (see Figure 6).
6. While firmly holding edges of trim together,
tighten both set screws on the adjusting plate
with slotted screwdriver.
7. Repeat steps 1 through 6 for other side.
8. Tighten trim hanging screws (#10 x 6.25
shoulder) into holes in cabinets. Place the
assembled trim onto fireplace cabinet. Align
hanging notches on trim with hanging screws
on side of fireplace (see Figure 7). Push trim
firmly into place, sliding hanging notches over
hanging screws.
INSTALLATION CLEARANCES
WARNING: Maintain the
minimum clearances. If you can,
provide greater clearances from
floor, ceiling and adjoining wall.
Carefully follow the instructions below. This will
ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 8.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/2" from the wall. This combus-
tible material must be 4" from the side of the
fireplace opening (see Figure 8).
B.
Clearances from the top of the fireplace opening
to the ceiling should not be less than 42 inches.