OPERATING FIREPLACE
Continued
Note: It is safe to operate fireplace with blower
turned off. However, the blower helps distribute
heated air from the fireplace.
Figure 44 - AUTO/OFF/ON Blower Switch
AUTO/OFF/ON Switch
REMOTE-READY MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighborʼs phone. Follow the gas
supplierʼs instructions.
• If you cannot reach your gas supplier, call
the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, donʼt
try to repair it, call a qualified service tech
-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D.
Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING: You must operate
this fireplace with the screen in
place. Make sure fireplace screen is
installed before running fireplace.
NOTICE: During initial opera-
tion of new fireplace, burning
logs will give off a paper-burn
-
ing smell. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.
WARNING: Burner will come
on automatically within one min-
ute when control valve is in the ON
position after the pilot is lit.
1. STOP! Read the safety information starting
in column 1.
2. Make sure equipment shutoff valve is fully
open.
3.
Press in and turn control knob clockwise
to the OFF position (see Figure 44).
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information, column 1. If you donʼt
smell gas, go to the next step.
5. Press in and turn control knob counter
-
clockwise
to the PILOT position.
Press in control knob for five (5) seconds
(see Figure 45).
Note: You may be running this fireplace for
the first time after hooking up to gas sup
-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
Figure 45 - Control Knob and Ignitor
Button Location (Shown as Supplied
- No Control Options)
Piezo
Ignitor
Button
Control
Knob
Flame
Adjustment
Knob