Desa FB32C Outdoor Fireplace User Manual


 
10
103296
INSTALLATION CLEARANCES
WARNING ICON G001
WARNING
Maintain the minimum clearances. If you can, provide greater
clearances from floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Wall and Ceiling Clearances (see Figure 6, page 11)
A. Clearances from the side of the firebox opening to any combustible wall should not
be less than 16 inches for a cabinet mantel or 12 inches for a corner installation.
B. Clearances from the top of the firebox opening to the ceiling should not be less
than 42 inches.
INSTALLING
NOTICE
A qualified service person must install firebox. Follow all local
codes.
WARNING ICON G001
WARNING
Never install the firebox
in a bedroom or bathroom
in a recreational vehicle
where curtains, furniture, clothing, or other flammable
objects are less than 36 inches from the front, top, or sides
of the firebox
in high traffic areas
in windy or drafty areas
WARNING ICON G001
CAUTION
Log heaters installed in this firebox create warm air currents.
These currents move heat to wall surfaces next to firebox. Install-
ing firebox next to vinyl or cloth wall coverings or operating
firebox where impurities in the air (such as tobacco smoke) exist,
may discolor walls.
IMPORTANT:
Vent-free gas log heaters add moisture to the air. Although this is
beneficial, installing firebox in rooms without enough ventilation air may cause
mildew to form from too much moisture. See Air for Combustion and Ventilation,
pages 6 through 9.
IMPORTANT:
Make sure the firebox is level. If firebox is not level, log set will not
work properly.