Desa EFS10TPA Outdoor Fireplace User Manual


 
www.desatech.com 112462-01B
24
OPERATING FIREPLACE
Continued
D. Do not use this appliance if any part has
been under water. Immediately call a quali-
fied service technician to inspect the appli-
ance and to replace any part of the control
system and any gas control which has been
under water.
LIGHTING
INSTRUCTIONS
WARNING: You must oper-
ate this fireplace with the screen
in place. Make sure fireplace
screen is installed before run-
ning fireplace.
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is
fully open.
3. Turn control knob clockwise
Clockwise
to the
OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information above. If you don’t smell
gas, go to the next step.
5. Turn control knob counterclockwise
C-clockwise
to the PILOT position. Press in control knob
for five (5) seconds (see Figure 36).
Note:
You may be running this fireplace
for the first time after hooking up to gas
supply. If so, the control knob may need to
be pressed in for 30 seconds or more. This
will allow air to bleed from the gas system.
If control knob does not pop out when
released, contact a qualified service per-
son or gas supplier for repairs.
6. With control knob pressed in, press and
release ignitor button (see Figure 36). This
will light pilot. The pilot is attached to the
front burner. If needed, keep pressing igni-
tor button until pilot lights.
Note:
If pilot does not stay lit, refer to
Troubleshooting, page 31. Also, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure on page 25.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note:
If pilot goes out, repeat steps 3
through 7. This fireplace has a safety inter-
lock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8. Turn control knob counterclockwise
C-clockwise
to desired heating level. The burner
should light. Set control knob to any heat
level between 5 (high) and 1 (low).
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Figure 36 - Control Knob In The OFF
Position
Electronic
Ignitor Button
Control Knob
Figure 37 - Natural Gas Pilot
Thermocouple
Ignitor Electrode
Pilot Burner
Figure 38 - Propane/LP Gas Pilot
Thermocouple
Ignitor
Electrode
Pilot
Burner