Desa CGCF26TPA Outdoor Fireplace User Manual


 
11
104278
OWNER’S MANUAL
CONNECTING TO GAS
SUPPLY
WARNING: A qualified service
person must connect fireplace to
gas supply. Follow all local codes.
CAUTION: Never connect fire-
place directly to the propane/LP
supply. This fireplace requires
an external regulator (not sup-
plied). Install the external regula-
tor between the fireplace and pro-
pane/LP supply.
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
or greater diameter to allow
proper gas volume to fireplace. If
pipe is too small, undue loss of
pressure will occur.
CAUTION: Use pipe joint seal-
ant that is resistant to liquid pe-
troleum (LP) gas.
The installer must supply an external regu-
lator. The external regulator will reduce
incoming gas pressure. You must reduce
incoming gas pressure to between 11 and 14
inches of water. If you do not reduce incom-
ing gas pressure, fireplace regulator damage
could occur. Install external regulator with
the vent pointing down as shown in Figure
16. Pointing the vent down protects it from
freezing rain or sleet.
Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
fireplace (see Figure 17).
Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
Install sediment trap in supply line as shown
in Figure 17. Locate sediment trap where it
is within reach for cleaning. Locate sedi-
ment trap where trapped matter is not likely
to freeze. A sediment trap traps moisture
and contaminants. This keeps them from
going into fireplace controls. If sediment
trap is not installed or is installed wrong,
fireplace may not run properly.
Propane/LP
Supply
Tank
Vent Pointing Down
External Regulator
ATTACHING WOOD BASE TO
SOLID FLOOR
For attaching base to solid floors (concrete
or masonry)
Note:
Floor anchors and mounting screws
are in hardware package. The hardware pack-
age is provided with fireplace.
1. Drill holes at marked locations using
5/16" drill bit. For solid floors (concrete
or masonry), drill at least 1" deep.
2. Fold floor anchor as shown in Figure 15.
Figure 15 - Folding Anchor
ASSEMBLING BRASS TRIM
(Brass trim shipped with
mantel)
1. Remove packaging from three remain-
ing pieces of brass trim.
2. Locate two adjusting plates with set
screws, and two shims in the hardware
packet.
3. Align shim under adjusting plate as
shown in Figure 14.
4. Slide one end of adjusting plate/shim
in slot on mitered edge of top brass trim
(see Figure 14).
5. Slide other end of adjusting plate/shim
in slot on mitered edge of side brass
trim (see Figure 14).
6. While firmly holding edges of brass
trim together, tighten both set screws
on the adjusting plate with slotted
screwdriver.
7. Repeat steps 1 through 6 for other
corner.
8. Set brass assembly aside for later in-
stallation.
Figure 14 - Assembling Brass Trim
INSTALLATION
Continued
3. Insert floor anchor (wings first) into
hole. Tap anchor flush to floor.
4. Insert mounting screws through base
and into floor anchors.
5. Tighten screws until base is firmly fas-
tened to floor.
Continued
Side Brass
Trim
Top Brass Trim
Mitered Edge
Shim
Set
Screws
Adjusting
Plate
Slot
Slot
Figure 16 - External Regulator with Vent
Pointing Down
A.G.A. Design-Certified
Manual Shutoff Valve
With 1/8" NPT Tap*
Approved Flexible
Gas Line
3" Minimum
From
External
Regulator
(11" W.C.
to 14" W.C.
Pressure)
Pipe Nipple Cap Tee Joint
Sediment Trap
* Purchase the optional A.G.A. design-cer-
tified manual shutoff valve from your dealer.
See Accessories, page 22.
Figure 17 - Gas Connection