This appliance shall only be used in an above ground open-air situation with natural ventilation, without stagnant
areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
Any outdoor enclosure in which the appliance is used shall comply with one of the following:
An enclosure with walls on all sides, but at least one premanent opening at ground level and no overhead cover.
See Fig.3.
Within a partial enclosure that includes an overhead cover and no more than two walls. See Figs. 4 & 5.
Within a partial enclosure that includes an overhead cover and more than two walls, the following shall apply:
- At least 25% of the total wall area is completely open and
- At least 30% of the remaining wall area is open and unrestricted. See Figs. 6 & 7.
In the case of balconies, at least 20% of the total of the side, back and front wall areas shall be and remain open
and unrestricted.
The following diagrams provide a diagrammatic representation of outdoor areas. Rectangular areas have been
used in these figures - the same principles apply to any other shaped area.
Fig. 3
Fig. 5 Fig. 6
Fig. 7
Fig. 4
INSTALLATION
LOCATING GRILL/BUILTIN CLEARANCES
9