GPF Dimensions
11¹⁄₂"
(292mm)
5"
(127mm)
12"
(305mm)
3¹⁄₄"(83mm)
16¹⁄₄"
(413mm)
11³⁄₈"
(289mm)
8¹⁄₄"
(210mm)
Burner
4237
Fig. 1 Physical dimensions.
Burner Assembly
Flex Line
Valve
Propane
Regulator/Hose
Natural
Gas Hose
FP1129
Fig. 2 GPF parts.
Gas Specifications
Max. Input
Model Fuel Btu/Hr
GPFMN Natural Gas 75,000
GPFMP Propane Gas 65,000
Gas Inlet Pressures
Natural LP (Propane)
Minimum Inlet Pressure 5.5” w.c. 11.0” w.c.
Maximum Inlet Pressure 14.0”w.c. 14.0” w.c.
Minimum Clearance to Combustibles
Inches mm
Floor 0 0
Side Walls 16 406
Top of unit to ceiling 7 ft. 2.1m