Vermont Casting CF9086 Gas Grill User Manual


 
Control Functions
PROPANE TANK VALVE
WARNING: Never open the Tank Valve unless the Grill is being prepared for use, to prevent the pooling of
propane vapor.
Always open the Valve immediately before lighting the Grill, and always close it immediately after cooking has
been completed.
BURNER CONTROL VALVES
On Model CF9030, three valves independently control gas flow to each burner, as indicated on the front
Control Panel.
On Model CF9055/56, four valves independently control gas flow to each burner, as indicated on the front
Control Panel.
On Model CF9085/86, there are five independent control valves for the main burners, and a separate control
valve for the rotisserie burner (see Fig. 7).
The OFF position is indicated by the dot above each knob. A full range of flame adjustment is available from
High to Low, (by turning a knob counterclockwise).
ELECTRONIC IGNITION SYSTEM (Models CF9055/56 & CF9085/86)
As you push the Igniter Button, you will hear a series of clicks as the igniter module generates an ignition
spark to the burners. The burner should light within four seconds. The system is powered by a single “AA”
battery. To remove or replace the battery, turn the push button knob counter clockwise, and carefully pull
out the spring and battery. Ensure that the positive end of the battery is in the down (bottom) position before
replacing the knob.
PIEZO IGNITION SYSTEM (Model CF9030)
As you turn the Ignitor Knob clockwise, you will hear a click as the Piezo module generates an ignition spark
to the burner. The burner should light within four seconds.
Operation
Page 6
Fig. 7
Rotisserie Burner Control
(Models CF9085/86 only)Igniter Button
Main Burners
(3, 4, or 5)