Brinkmann Kettle Grill Charcoal Grill User Manual


 
TROUBLE SHOOTING:
Problem: Possible Causes:
Burner will not light
1. Check LP cylinder fuel level.
2. Bad electrode spark.
Check to see if the grill will match light.
Electrode or collector may need adjustment.
3. Venturi may not be properly seated.
4. Venturi may be obstructed.
5. The cylinder valve may be closed.
6. Regulator is not properly seated on cylinder valve.
Fire at control knob 1. Venturi is obstructed. See section on
Cleaning and Maintenance of the Venturi.
2. Venturi is improperly seated on control valve.
3. Gas connections may be loose.
Leak Check and tighten all connections.
Yellow Flames at burner 1. Venturi is obstructed. See section on
Cleaning and Maintenance of the Venturi.
Flame blows out on "LOW" 1. Venturi may be obstructed. See section on
Cleaning and Maintenance of the Venturi.
2. Grill is not sufficiently preheated.
3. Venturi is improperly seated on control valve.
Burner does not get hot enough 1. Flow control device has been activated in regulator.
2. Turn off the grill and the fuel supply. Disconnect the
grill from the cylinder valve. Reconnect the grill to
the cylinder and light grill. See section on
Connection to the LP Cylinder.
Grill is Too Hot 1. Excess grease build-up causing grease fires.
2. Damaged or faulty regulator.
Replace with factory authorized parts.
3. Cook on a lower temperature setting.
14