6
Step 4
Remove two screws from each
burner "foot" using a screwdriver.
Remove wood chip drawer to get
access to the wood chip burner.
Remove one screw from the wood
chip burner. Carefully lift each burner
up and away from valve openings.
Set aside for later use.
Step 5
Using the gas orifice tool, remove
the LP brass orifice from the tip of
each gas valve assembly. Repeat
this step for all main burner and
wood chip burner valves in your
grill.
Note: All orifices of the grill, except
rotisserie, are double orifices
type (LP gas and natural gas).
You only remove the LP gas
orifice tip.
Step 6
Remove all the control knobs from the
control panel and set aside for later
use.
Step 7
Figure 1 shows valve stem and bezel
with both screws. Place stop plate over
valve stem as shown in Figure 2. Verify
the tab and the stamped letter on the
stop plates face out. Replace control
knobs when finished.
WARNING: We recommend and
request that you do not remove the
control panel in order to access the
valve tips. If you choose to remove
the control panel, you must replace
the control panel bezels exactly as
illustrated in Figure 2. Failure to
replace the bezels as illustrated
could lead to personal injury and/or
property damage.
L
Figure 2
Figure 1
Stop Plate
Gas Orifice Tool
Side View
LP Gas Orifice
Wood Chip Drawer
Fire Box Front Panel
Stop Pin
Tab