CHECKING FOR LEAKS:
1. Create a mixture of 50% water and 50% liquid dishwashing soap.
2. Open the lid.
3. Ensure all control knobs are set to the "OFF" position.
4. Ensure gas hose is tightly connected to gas source.
5. Turn on the fuel supply on at the source.
6. Apply the soap water mixture to the following:
Note: Some Grill models will have different connections than illustrated.
Hose connection to gas manifold.
Gas supply hose connection to
side burner valve assembly.
Side burner valve stem cap. (if applicable)
Side burner connection to hose. (if applicable)
The full length of gas supply hose.
Rotisserie orifice connection. (if applicable)
Rotisserie supply line connection to rotisserie valve assembly. (if applicable)
Note:
Rotisserie gas supply line can be gas leak tested by removing the grease tray and applying soap
water mixture from under the control panel.
Quick disconnect coupler.
H
G
F
E
D
C
B
A
36
Before first use, check gas supply line connection to rotisserie burner
valve (under control panel) and gas supply line connection to the
orifice (back of grill body). Push in and turn the rotisserie control knob
to “HIGH” and hold in the knob when performing gas leak test on
rotisserie valve. Allow gas to dissipate when finished.
CAUTION:
H
GF
A
B
C
D
E