Brinkmann 4905 Gas Grill User Manual


 
10
Step 10
Loosen nut and detach gas line
from rotisserie burner valve.
NOTE: Bending the hose could
damage the supply line.
Step 11
Carefully pull the gas manifold out
from the burner tubes to allow
access to the thermal couple nut.
Remove thermal couple nut from
the back of the rotisserie burner
valve. Remove the existing LP gas
manifold.
Step 12
Remove two screws on the access
panel located on the back of the
rotisserie burner. Remove panel.
NOTE: Leave panel off until the end
of conversion and all gas
leak testing has been done.
Thermal Couple Nut
Nut
Access Panel Screws
Natural Gas Manifold
Rotisserie Burner Valve
Gas Line