4.2 CHECK GAS PRESSURE
Remove the pressure test point screw located on the
injector feed pipe just left of centre on the fire. Connect a
pressure gauge, slide the control knob down to the
PILOT/IGNITION position. Keep the knob depressed
after the pilot has lit to activate the FSD and then slide the
knob to the HIGH position. Check that the gas pressure is
as specified in Section 1.0 Technical Data. Turn off the fire
and disconnect the pressure gauge. Replace the test
point screw, relight the fire and test for gas soundness
around the sealing screw using a suitable leak detection
fluid.
4.3 FIT OUTER CASE
Align the bottom cut-outs in the outer case with the
retaining lugs on the firebox sides. Raise the outer case
vertically and then lower to engage the top onto the lugs
above the air guide, at the same time ensure that the
bottom cut-outs remain on the retaining lugs.
Fig. 7C