OPERATION
GENERAL OPERATIONAL NOTES
Carefully read the description of the charbroiler operation on the
specication sheet.
Do NOT use this appliance if it has been submerged in water. Call a
qualied technician to examine the appliance and to service or replace
any component which has been submerged. Burners which have
been allowed to become wet must be thoroughly dried before use.
For initial startup, and any time the gas supply has been shut-off, it
may take several minutes to light the pilot while air in the piping and
manifolds is purged.
The burner control knobs must be turned by hand only. Never use
tools to turn the control knob. If the knob will not turn by hand, DO
NOT attempt to force or repair it. Contact your Authorized Wells
Service Agency for repairs. Forced or improperly repaired valves
pose the risk of re and/or explosion.
Make sure burners, pilot burner and drip tray are properly installed
before attempting to operate.
LIGHTING THE PILOT FLAME
Before lighting the pilot light, smell all around the appliance area for
gas. Be sure to smell near oor level because some gas is heavier
than air and will settle to the oor.
For initial startup, and any time the gas supply has been shut-off, it
may take several minutes to light the pilot while air in the piping and
manifolds is purged.
The pilot light must be lighted by hand:
Remove grates. Turn all control knobs to the full OFF position.
Wait 5 minutes.
The pilot is located adjacent to the burner, and is accessible from
the top of the unit.
Be sure the gas shut-off valve is ON and the appliance has had time
for the air to be purged from the lines. Attempt to light the pilot every
15 seconds after the gas valve is turned on.
Light the pilot with a long match or replace lighter.
DO NOT use a cigarette lighter.
Reinstall grates
SHUT DOWN INSTRUCTIONS
Turn all burner knobs to OFF.
Turn all pilots OFF.
Turn the main gas supply OFF.
WARNING:
FIRE HAZARD
IF YOU SMELL GAS:
¤ DO NOT try to light any
appliance.
¤ DO NOT touch any
electrical switch
¤ DO NOT use any
telephone in your building.
In the event a gas odor is
detected, shut down the unit at
the main gas shutoff valve and
contact your local gas supplier
from a neighboring location.
Follow the instructions
received from the gas supplier
immediately and exactly.
8
M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers
M163 2M-306981 Owners Manual for HDCB-Series Gas Char-Broilers