Weber Silver C Gas Grill User Manual


 
D-5
Side Burner maintenance
ƽ WARNING: All gas controls and supply valves
should be in the OFF position.
Check igniter: Remove side burner cover. To remove side
burner cover, remove control knob and screws that hold
cover to bottom(1).
Problem Check Cure
Side Burner does not light.
Flame is low in HIGH position.
Flame is very yellow in
conjunction with the smell of gas,
OR
Burner makes popping noise in
conjunction with the smell of gas.
Push button ignition does not
work.
Is gas supply off?
Turn supply on.
Is the fuel hose bent or kinked? Straighten hose.
Inspect the Weber
®
Insect / Spider
Screens for possible obstructions.
(lockage of holes.)
Clean Weber
®
Insect / Spider
Screens (See section Annual
Maintenance)
Does burner light with a match?
If match lights burner, checkigniter
(see below).
Make sure wire is connected between igniter and
electrode. Check that igniter lock nut is tight.
Note: If the igniter works loose, carefully tighten the igniter
lock nut with an adjustable wrench or pliers.
Adjust igniter electrode to burner. Gap should be 1/8 to 3/
16 inch from tip of electrode to burner. Spark should be a
white/blue color, not yellow.
1) Igniter
2) Igniter Wire
3) Venturi/Burner
4) 1/8 to 3/16 inch gap between electrode and burner
Side Burner Troubleshooting
(4)
(1)
(2)
(3)