GAS INSTRUCTIONS
m DANGER
Do not store a spare LPG gas cylinder under or near this
appliance. Never fill the cylinder beyond 80 percent full. If the
instructions are not followed exactly, a fire causing death or
serious injury may occur.
ATTACH PROPANE CYLINDER
Use propane cylinders with a minimum capacity of 4.5 kg and a maximum capacity of 9 kg.
m CAUTION: Use cylinders that are marked “Liquid Propane
fuel” only.
Connect the hose and the regulator to the cylinder.
Note: Regulator vent hole should be pointed down.
m WARNING: The regulator has left hand screw threads. It
tightens by turning counterclockwise.
m WARNING: No sealant is required on the POL fitting. Do not
use pipe dope, tape or any other sealant on the POL fitting
or LPG cylinder.
Use your fingers to start the POL fitting in the LPG cylinder valve. Turn nut
counterclockwise until tight.
m WARNING: Do not use a wrench to tighten the connection.
Using a wrench could damage the regulator coupling and
could cause a leak.
2
3
Hose
Regulator
POL fitting nut -
tighten
counterclockwise
Valve handwheel -
close clockwise
Regulator vent hole
1
CHECK FOR GAS LEAKS
m DANGER
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames in the area while you
check for leaks. Sparks or flames will result in a fire or
explosion which can cause serious bodily injury or death,
and damage to property.
Check for leaks by wetting the connections with a soap and water solution and watching
for bubbles. If bubbles form, or if a bubble grows, there is a leak.
A) Regulator to propane cylinder connection (2).
m WARNING: If there is a leak at connection (2), disconnect
propane cylinder. Reconnect and retighten connection. If a
leak persists after retightening the propane cylinder, turn
OFF the gas. DO NOT OPERATE THE BARBECUE. Contact
the Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
B) Valve to-regulator connections (3).
m WARNING: If there is a leak at connection (3) turn OFF
the gas. DO NOT OPERATE THE BARBECUE. Contact the
Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at the source and rinse
connections with water.