Weber 38026 Gas Grill User Manual


 
9
(8)
(2)
(4)
(6)(7)
(1)
(3)
GAS INSTRUCTIONS
(5)
(3)
(2)
(1)
(4)
Check:
1) Hose connection.
2) Gas line to manifold connections.
ƽ WARNING: If there is a leak at connection (1, or 2),
retighten the fi tting with a wrench and recheck for
leaks with soap and water solution.
If a leak persists after re-tightening the fi tting, turn
OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site. Log onto www.weber.com
®
.
3) Regulator to cylinder connection.
4) Hose to regulator connection.
5) Valves to manifold connections.
ƽ WARNING: If there is a leak at connections (3,4, or 5),
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site. Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at the source and
rinse connections with water.
Check:
1) Hose connection.
2) Gas line to manifold connections.
3) I.R. Burner gas line connection.
ƽ WARNING: If there is a leak at connection (1,2, or 3),
retighten the fi tting with a wrench and recheck for
leaks with soap and water solution.
If a leak persists after re-tightening the fi tting, turn OFF
the gas. DO NOT OPERATE THE GRILL. Contact the
Customer Service Representative in your area using
the contact information on our web site. Log onto www.
weber.com
®
.
4) Side burner hose to manifold connection
5) Side burner hose to side burner connection, and sideburner valve to
orifi ce
6) Regulator to cylinder connection.
7) Hose to regulator connection.
8) Valves to manifold connections.
ƽ WARNING: If there is a leak at connections (4,5,6,7,
or 8), turn OFF the gas. DO NOT OPERATE THE GRILL.
Contact the Customer Service Representative in your
area using the contact information on our web site. Log
onto www.weber.com
®
.
When leak checks are complete, turn gas supply OFF at the source and
rinse connections with water.
SUMMIT
®
A
SUMMIT
®
B, D