Weber Platinum B Gas Grill User Manual


 
C-1
Check that all burner valves are off
You will need: burner control knobs.
Valves are shipped in the OFF position, but you should
check to be sure that they are turned OFF. Put the
knob on each valve. Check by pushing down and
turning clockwise. If they do not turn, they are off.
Proceed to the next step. If they do turn continue
turning them clockwise until they stop, then they are
off. Proceed to the next step.
Installing Work Surfaces &
Gas Connection Guidelines
C019.a
Install Left Work Surface
You will need left work surface, two 1/2 inch bolts, two
nylon washers and a 7/16 inch or adjustable wrench.
Insert the left work surface tabs in the slots in the
frame(1). Slip washers on the bolts and insert the bolts
as shown(2). Tighten
(1)
(2)
Install Gas Supply
General Specifications for Piping
Note - Contact your local municipality for building
codes regulating outdoor gas barbecue installa-
tions. In absence of Local Codes, you must con-
firm to the latest edition of ANSI Z223.1. WE REC-
OMMEND THAT THIS INSTALLATION BE DONE BY
A PROFESSIONAL.
Some of the following are general requirements taken
from ANISI Z223.1 latest edition for complete specifi-
cations.
This barbecue is designed to operate at 7 inches of
water column pressure (.2526 psi).
A manual shut-off valve must be installed outdoors,
immediately ahead of the quick disconnect.
An additional manual shut-off valve indoors should
be installed in the branch fuel line in an accessible
location near the supply line
The quick disconnect connects to a 3/8 inch NPT
thread from the gas source. The quick disconnect
fitting is a hand-operated device that automatically
shuts OFF the flow of gas from the source when the
barbecue is disconnected
The quick disconnect fitting can be installed horizon-
tally, or pointing downward. Installing the fitting with the
open end pointing upward can result in collecting
water and debris.
The dust covers (supplied plastic plugs) help keep
the open ends of the quick disconnect fitting clean
while disconnected.
Pipe compound should be used which is resistant to
the action of natural gas when connections are made.
The outdoor connector must be firmly attached to
rigid, permanent construction.
ƽ WARNING: Do not route the 12 foot hose under
a deck. The hose must be visible.
Gas supply
Shut off
Locking shut off
Inside wall
Outside wall
Quick Disconnect