(2)
Check for gas leaks
Note - All factory-made connections have been
thoroughly checked for gas leaks. The burners have
been flame-tested. As a safety precaution however,
you should recheck all fittings for leaks before using
your Weber Gas Barbecue. Shipping and handling may
loosen or damage a gas fitting.
To perform leak checks: Slide back the collar of the
quick disconnect. Push male fitting of the hose into the
quick disconnect, and maintain pressure(1). Slide the
collar closed(2). If it does not engage or lock, repeat
procedure. Gas will not flow unless the quick discon-
nect is properly engaged.
Turn on gas supply.
ƽWARNING: Do not ignite burners while checking
for leaks.
Check for leaks by wetting the connections with the
soap and water solution and watching for bubbles. If
bubbles form or if a bubble grows, there is a leak.
(1)
(2)
(4)
(3)
(5)
(6)
Check:
1) Hose to manifold connection.
ƽWARNING: if there is a leak at connection(1),
retighten the fitting with a wrench and recheck
with the soap and water solution
If a leak persists after retightening the fitting, turn
OFF the gas. DO NOT OPERATE THE BARBECUE.
Contact the Customer Service Representative in
your region using the contact information sheet
provided with your manual.
2) Manifold to side burner hose connection.
3) Valves to manifold connections.
4) Hose to quick disconnect connection.
5) Side burner supply line to side burner orifice
connection. (view from below)
6) Side burner hose to side burner valve, and
side burner supply line to side burner valve.
(view from below)
ƽWARNING: If there is a leak at connections
2,3,4,5 or 6 turn OFF the gas. DO NOT OPERATE
THE BARBECUE. Contact the Customer Service
Representative in your region using the contact
information sheet provided with your manual.
When leak checks are complete, turn gas supply OFF
at the source and rinse connections with water.