Weber E/S-310, E/S-320 Gas Grill User Manual


 
9
WWW.WEBER.COM
®
9
GENERAL INSTRUCTIONS
GENERAL INSTRUCTIONS
Slide out Bottom tray - Remove excess grease, then wash with warm soapy water,
then rinse.
Flavorizer
®
bars and Cooking grates - Clean with a suitable brass bristle brush. As
needed, remove from grill and wash with warm soapy water, then rinse with water.
Catch pan - Disposable foil trays are available, or you can line the catch pan with
aluminum foil. To clean the catch pan, wash with warm soapy water, then rinse.
Thermometer - Wipe with warm soapy water; clean with plastic scrub ball.
Inside cooking module - Brush any debris off of burner tubes. DO NOT ENLARGE
BURNER PORTS (OPENINGS). Wash inside of cooking box with warm soapy water
and a water rinse.
Inside Lid - While lid is warm, wipe inside with paper towel to prevent grease build-up.
Flaking built-up grease resembles paint fl akes.
Stainless steel surfaces - Wash with a soft cloth and a soap and water solution. Be
careful to scrub with the grain direction of the stainless steel.
Do not use cleaners that contain acid, mineral spirits or xylene. Rinse well after
cleaning.
Preserve Your Stainless Steel
Your grill or its cabinet, lid, control panel and shelves may be made from stainless steel.
To keep the stainless steel looking its best is a simple matter. Clean it with soap and
water, rinse with clear water and wipe dry. For stubborn particles, the use of a non-
metallic brush can be used.
ƽ IMPORTANT: Do not use a wire brush or abrasive cleaners
on the stainless steel surfaces of your grill as this will cause
scratches.
ƽ IMPORTANT: When cleaning surfaces be sure to rub/wipe in
the direction of the grain to preserve the look of your stainless
steel.
GAS INSTRUCTIONS
INSTALL GAS SUPPLY
General Specifi cations for Piping
Note: Contact your local municipality for building codes regulating outdoor gas
barbecue installations. In absence of Local Codes, you must conform to the
latest edition of the National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-
B149.1, Natural Gas and Propane Installation Code. WE RECOMMEND THAT THIS
INSTALLATION BE DONE BY A PROFESSIONAL.
Some of the following are general requirements taken from the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas and
Propane Installation Code for complete specifi cations.
This barbecue is designed to operate at 7 inches of water column pressure (.2526
psi).
A manual shut-off valve must be installed outdoors, immediately ahead of the quick
disconnect.
An additional manual shut-off valve indoors should be installed in the branch fuel
line in an accessible location near the supply line.
The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The
quick disconnect fi tting is a hand-operated device that automatically shuts off the
fl ow of gas from the source when the barbecue is disconnected.
The quick disconnect fi tting can be installed horizontally, or pointing downward.
Installing the fi tting with the open end pointing upward can result in collecting water
and debris.
The dust covers (supplied plastic plugs) help keep the open ends of the quick
disconnect fi tting clean while disconnected.
Pipe compound should be used which is resistant to the action of natural gas when
connections are made.
The outdoor connector must be fi rmly attached to rigid, permanent construction.
ƽ WARNING: Do not route the 10 foot hose under a deck. The
hose must be visible.
Gas Line Piping
If the length of the line required does not exceed 50 feet, use a 5/8" O.D. tube. One
size larger should be used for lengths greater than 50 feet.
Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a
minimum wall thickness of .062 inch; or standard weight (schedule 40) steel or
wrought iron pipe.
Copper tubing must be tin-lined if the gas contains more than 0.3 grams of
hydrogen sulfi de per 100 cubic feet of gas.
Plastic tubing is suitable only for outdoor, underground use.
Gas piping in contact with earth, or any other material which may corrode the
piping, must be protected against corrosion in an approved manner.
Underground piping must have a minimum of 18" cover.
Test Connections
All connections and joints must be thoroughly tested for leaks in accordance with local
codes and all listed procedures in the latest edition of the National Fuel Gas Code: ANSI
Z 223.1/NFPA 54, or CAN/CGA-B149.1
ƽ DANGER
Do not use an open fl ame to check for gas leaks. Be sure
there are no sparks or open fl ames in the area while you
check for gas leaks. This will result in a fi re or explosion
which can cause serious bodily injury or death and damage
to property.
Gas supply
Shut off
Locking shut off
Inside wall
Outside wall
Quick
disconnect
3
/
8
" Pipe
nipple
1
/
2
" Pipe
nipple
Do Not Use
This is a typical installation
of a Weber
®
natural gas
barbecue. Local codes may
require different
installations.