Weber 89527 Gas Grill User Manual


 
7
WWW.WEBER.COM
®
7
ƽ CAUTION: Do not clean your Flavorizer
®
bars or cooking
grates in a self-cleaning oven.
For availability of replacement cooking grates and Flavorizer
®
bars Contact the
Customer Service Representative in your area using the contact information on
our web site. Log onto www.weber.com
®
.
Slide out Bottom tray - Remove excess grease, then wash with warm soapy water,
then rinse.
Catch pan - Disposable foil trays are available, or you can line the catch pan with
aluminum foil. To clean the catch pan, wash with warm soapy water, then rinse.
Thermometer - Wipe with warm soapy water; clean with plastic scrub ball.
Inside cooking module - Brush any debris off of burner tubes. DO NOT ENLARGE
BURNER PORTS (OPENINGS). Wash inside of cooking box with warm soapy water
and a water rinse.
Inside Lid - While lid is warm, wipe inside with paper towel to prevent grease build-up.
Flaking built-up grease resembles paint flakes.
Stainless steel surfaces - Preserve Your Stainless Steel - Your grill or its cabinet,
lid, control panel and shelves may be made from stainless steel. In order to keep the
stainless steel looking its best is easy. Simply clean it with soap and water, rinse with
clean water and wipe dry. A non-metallic brush can be used for stubborn stains.
ƽ IMPORTANT: Do not use wire brushes or abrasive cleaners
on the stainless steel surfaces of your grill, as this will leave
scratches.
ƽ IMPORTANT: Do no use cleaners that contain chlorine
bleach on the stainless steel surface of your grill.
ƽ IMPORTANT: When cleaning surfaces, be sure to rub/wipe
in the direction of the grain to preserve the look of your
stainless steel.
Thermoset surfaces - Wash with a soft cloth and a soap and water solution.
Do not use cleaners that contain acid, mineral spirits or xylene. Rinse well after
cleaning.
Thermoset work surfaces are not to be used as cutting boards.
GENERAL INSTRUCTIONS
GAS INSTRUCTIONS
INSTALL GAS SUPPLY
General Specifications for Piping
Note: Contact your local municipality for building codes regulating outdoor gas barbecue
installations. In absence of Local Codes, you must confirm to the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas and
Propane Installation Code. WE RECOMMEND THAT THIS INSTALLATION BE DONE
BY A PROFESSIONAL.
Some of the following are general requirements taken from the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas and
Propane Installation Code for complete specifications.
This barbecue is designed to operate at 7 inches of water column pressure (.2526
psi).
A manual shut-off valve must be installed outdoors, immediately ahead of the quick
disconnect.
An additional manual shut-off valve indoors should be installed in the branch fuel
line in an accessible location near the supply line
The quick disconnect connects to a 3/8 inch NPT thread from the gas source. The
quick disconnect fitting is a hand-operated device that automatically shuts off the
flow of gas from the source when the barbecue is disconnected
The quick disconnect fitting can be installed horizontally, or pointing downward.
Installing the fitting with the open end pointing upward can result in collecting water
and debris.
The dust covers (supplied plastic plugs) help keep the open ends of the quick
disconnect fitting clean while disconnected.
Pipe compound should be used which is resistant to the action of natural gas when
connections are made.
The outdoor connector must be firmly attached to rigid, permanent construction.
ƽ WARNING: Do not route the 10 foot hose under a deck. The
hose must be visible.
GAS LINE PIPING
If the length of the line required does not exceed 50 feet, use a 5/8" O.D. tube. One
size larger should be used for lengths greater than 50 feet.
Gas piping may be copper tubing, type K or L; polyethylene plastic tube, with a
minimum wall thickness of .062 inch; or standard weight (schedule 40) steel or
wrought iron pipe.
Copper tubing must be tin-lined if the gas contains more than 0.3 grams of
hydrogen sulfide per 100 cubic feet of gas.
Plastic tubing is suitable only for outdoor, underground use.
Gas piping in contact with earth, or any other material which may corrode the
piping, must be protected against corrosion in an approved manner.
Underground piping must have a minimum of 18" cover
TEST CONNECTIONS
All connections and joints must be thoroughly tested for leaks in accordance with local
codes and all listed procedures in the latest edition of the National Fuel Gas Code: ANSI
Z 223.1/NFPA 54, or CAN/CGA-B149.1
ƽ DANGER
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames in the area while you
check for gas leaks. This will result in a fire or explosion
which can cause serious bodily injury or death and damage
to property.