Weber 62434 Gas Grill User Manual


 
7
WWW.WEBER.COM
®
INSTALLATION
LOCATING YOUR BUILT-IN SIDE BURNER APPLIANCE
When determining a suitable location for your Built-In Side Burner installation, give
attention to concerns such as exposure to wind, proximity to traffic paths, and keeping
any gas supply lines as short as possible. Never locate the Summit
®
Built-In Side Burner
in a garage, breezeway, shed, under overhang, or other enclosed area. Locate the Side
Burner and structure so there is enough room to safely evacuate the area in case of a
fire.
CLEARANCE FROM COMBUSTIBLE SURFACES OR STRUCTURES
ƽ WARNING: Clearance from the outside walls of the sides
and back of the Built-In Side Burner must be a minimum
of 24 inches (61 cm) from any combustible surface. Refer
to “Installation/Gas Instructions” section before starting
installation.
C
A
B
BUILT-IN STRUCTURE CUTOUT DIMENSIONS
All dimensions are to finished surfaces.
ƽ WARNING: All counter top finished surfaces must be
constructed of a noncombustible material.
SIDE BURNER
Cut out Dimensions Tolerances
A 12 3/8" (31.4 cm) + 1/8" - 1/8" (3.18mm)
B 7 7/8" (20 cm) -
C 27" (68.6 cm) + 1/8" - 1/8" (3.18mm)
C
A A
B
B
B
1
SIDE BURNER LOCATION
A Any Surface
B 24" (61 cm) From Any Combustible Surface
C Side Burner
1
Note: For a countertop treatment: Recommended 3/4" (19 mm) overhang.
Notch front edge for frame to fully slide in.
ƽ DANGER
The structure, “island” counter tops and adjacent work areas
for the Built-In Side Burner installation must be built from
noncombustible materials only. Incorrect installation may
result in a fire, which can cause serious bodily injury or
death, and cause damage to property.
NOTE: If you have questions on what materials are considered noncombustible, contact
you local building supplier or fire department.