Weber 56216 Gas Grill User Manual


 
12
GAS INSTRUcTIoNS
Check:
A) Bulkhead and gas supply hose connection (1).
B) Bulkhead to regulator connection (2).
C) Regulator to hose connection (3).
D) Main gas line to manifold connections (4).
m WARNING: If there is a leak at connection (1, 2, 3, or 4),
retighten the fitting with a wrench and recheck for leaks with
soap and water solution.
If a leak persists after re-tightening the fitting, turn off the gas.
DO NOT OPERATE THE GRILL. Contact the Customer Service
Representative in your area using the contact information on
our web site. Log onto www.weber.com
®
.
E) Bulk head to side burner hose connection (5).
F) Side burner hose to quick disconnect connection, side burner valve and orifice
connections (6).
G) Hose to quick disconnect connection (7).
H) Valves to manifold connections (8).
m WARNING: If there is a leak at connections (5, 6, 7, or 8),
turn off the gas. DO NOT OPERATE THE GRILL. Contact
the Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply off at the source and rinse connections
with water.
Reinstall Control Panel
Parts required: control panel, screws and burner control knobs.
A) Hook the top edge of the control panel onto the control panel brackets on either side
of the front of the cooking box.
B) Line up screws with screw holes on both the control panel bracket and the frame.
Tighten screws.
C) Place corresponding control knobs onto the valve stems.
1
2
3
4
5
6
7
8
The grill illustrated may have slight
differences than the model purchased.