Check:
a) Hose to manifold connection. Figure 3 (a).
ƽWARNING: If there is a leak at the hose to manifold
connection, Figure 3 (a), retighten the hose fitting with
a wrench and recheck for leaks with soap and water
solution.
If a leak persists after retightening the fitting, turn OFF
the gas. DO NOT OPERATE THE BARBECUE. Contact
Weber-Stephen Customer Service.
b) Valves to manifold connections. Figure 3 (b).
c) The hose to quick disconnect connection. Figure 3 (c).
ƽWARNING: If there is a leak at connections b or c,
turn OFF the gas. DO NOT OPERATE THE BARBECUE.
Contact Weber-Stephen Customer Service.
When leak checks are complete, turn gas supply OFF at
the source and rinse connections with water.
Inspection and Cleaning of the Weber Spider
Stopper Guards
To inspect the Spider Stopper Guards, remove the control
panel and look to see if they have dust or dirt on their
outside surfaces. If they are dirty, brush off the outside
surface of the Spider Stopper Guards with a soft bristle
brush (an old toothbrush for example). Check that there
are no gaps in the Spider Stopper Guards’ seams or in the
fit around the burners or valves. (See Section "General
Maintenance".)
Annual Maintenance
After a period of nonuse we recommend that you perform
the following maintenance procedures for your safety.
ƽWARNING: Check hose before each use of barbecue
for nicks, cracking, abrasions or cuts. If the hose is
found to be damaged in any way, do not use the
barbecue. Replace using only Weber authorized
replacement hose. Order from Weber-Stephen Products
Co., Customer Service Center or authorized dealer.
Inspect the burners for correct flame pattern. Clean if
necessary, following the procedures outlined in the
"General Maintenance" section of this manual.
Check all gas fittings for leaks.
ƽ DANGER
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for
leaks. This will result in a fire or explosion
which can cause serious bodily injury or
death, and damage to property.
(a)
Figure 3
(c)
(b)
ƽWARNING: You should check for gas leaks every
time you disconnect and reconnect a gas fitting.
Note - All factory made connections have been thoroughly
checked for gas leaks. The burners have been flame
tested. As a safety precaution you should recheck all
fittings for leaks before using your Weber Gas Barbecue.
Shipping and handling may have loosened or damaged a
gas fitting.
ƽWARNING: Perform these leak checks even if your
barbecue was dealer or store assembled.
You will need: a soap and water solution and a rag or
brush to apply it.
To perform leak checks: Plug end of gas supply hose into
the quick disconnect, then turn on gas supply.
ƽWARNING: Do not ignite burners while leak checking.
Check for leaks by wetting the connections with the soap
and water solution and watching for bubbles. If bubbles
form or if a bubble grows there is a leak.
Note - Since some leak test solutions, including soap and
water, may be slightly corrosive, all connections should be
rinsed with water after checking for leaks.