Viking VGBQ412-2RT/E* Gas Grill User Manual


 
VGBQ410-3RT/E*
T-Series/E-Series
Three-Burner All-Grill
VGIQ412-2RT*
T-Series Two-Burner Grill
w/Side Burners
(inc. TruSear™ Burner)
VGBQ412-2RT/E*
T-Series/E-Series
Two-Burner Grill
w/Side Burners
VGIQ410-3RT/E*
T-Series /E-Series
Three-Burner All-Grill
(inc. TruSear™ Burner)
GAS
Fixed piping installations
• Check with local gas utility
company or with local codes
for instructions on installing
gas supply lines. All gas
connections should be made
by a competent technician and
in accordance with local codes
and or ordinances. In the
absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
• An installer-supplied gas shut-
off valve must be installed in
an easily accessible location.
All installer-supplied parts
must conform to local codes.
• Must be isolated from the gas
supply piping system by
closing its individual manual
shut-off valve during any
pressure testing of that system
at test pressures equal to or
less than 1/2 psi (3.5 kPa).
Natural gas models
Water column pressure
o Operating pressure—4.0"
WCP
o Supply pressure of 6" – 14"
WCP
o If incoming pressure exceeds
14" WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.
LP/propane models
Water column pressure
o Operating pressure—10” WCP
o Supply pressure of 11” – 14”
WCP (for fixed piping
installations)
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.
LP/propane tank installations
Water column pressure
o Operating pressure—10”
WCP
Includes high-capacity
hose/regulator assembly for
connection to a standard 5-
gal./20-lb. (approx. 12”
diameter/18”H.) LP/propane
gas cylinder equipped with a
Type 1, QCC-1 connector
o The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.
o The cylinder must be
provided with a shut-off
valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified.
o The cylinder supply system
must be arranged for vapor
withdrawal and provided with
a listed OPD (overfilling
prevention device).
ELECTRICAL
T-Series models
o 9-volt DC battery for
electronic ignition
o 2’ (61.0 cm) power cord
supply cord with 3-prong
grounded plug attached to
rotisserie motor.
120 VAC/60 Hz
o Rotisserie motor max. amp
usage—6.0
E-Series models
o 3’ (91.4 cm) power cord
supply cord with 3-prong
grounded plug attached to
grill
120 VAC/60 Hz
o 120 VAC/60 Hz
o Grill max. amp usage
VGBQ/VGIQ410—2.2
VGBQ/VGIQ412—2.3
o 2’ (61.0 cm) power cord
supply cord with 3-prong
grounded plug attached to
rotisserie motor.
120 VAC/60 Hz
o Rotisserie motor max. amp
usage—6.0
PLUMBING
Not applicable
UTILITY
REQUIREMENTS
OUTDOOR—COOKING
41”W. Ultra-Premium T-Series/E-Series Gas Grill
PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM 1-888-VIKING1
RELEASED 05/12/08
©2007 VRC—INFORMATION SUBJECT TOCHANGE
Installation Requirements
VGBQ410-3RT VGBQ412-2RT/E VGIQ410-3RT/E VGIQ412-2RT
Burner rating
Standard SS grill burners (each) 25,000 BTU (7.3 kW) Nat./22,500 BTU (6.5 kW) LP
Smoker burner (split standard) 12,500 BTU (3.7 kW) Nat./10,500 BTU (3.1 kW) LP
GourmetGlo™ rotisserie burner 15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
Side grill burners (each) 15,000 BTU (4.4 kW) Nat./13,500 BTU (4.0 kW) LP
TruSear infrared burner
3
0,000 BTU (8.8 kW) Nat./LP
3
0,000 BTU (8.8 kW) Nat./LP