Viking TruSearTM Gas Grill User Manual


 
3
GGAASS CCOONNNNEECCTTIIOONN
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the rating plate
agrees with that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut-
off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or
in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1.
IInn CCaannaaddaa::
Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation
Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes. All pipe sealants must be an approved type
and resistant to the actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by
a competent technician and in accordance with local codes and or ordinances. In the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.
The gas burner and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa). The unit must be isolated
from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that
system at test pressures equal to or less than 1/2 psi (3.5 kPa).
BBAASSIICC SSPPEECCIIFFIICCAATTIIOONNSS
DDeessccrriippttiioonn
VVGGIIBB115511TT
VVGGIIBB224422TT
Overall Width 15-5/16” (38.9 cm) 26 1/4” (66.7 cm)
Overall Depth
To end of landing ledge 31-9/16” (80.2 cm)
To end of knobs 32-5/8” (82.9 cm)
Overall Height 10 1/2” (26.3 cm)
Cutout Width 14” (35.6 cm) 24 3/4” (62.9 cm)
Cutout Depth 27-1/2” (69.9 cm)
Cutout Height 10-1/4” (26.0 cm)
Gas Natural: standard residential 1/2” (1.3 cm) ID gas service line.
Requirements LP/Propane: equipped with high capacity hose/regulator assembly for
connection to standard 5gal, 20 lb. LP/Propane gas cylinder
with Type 1, QCC-1 connection or standard residential 1/2”
(1.3 cm) ID gas service line.
Infrared Burner 21,500 BTU Nat./20,000 BTU LP
Rating (6.3 kW Nat./5.9 kW LP)
Approximate Shipping 55 lbs. (24.8 kg) 160 lbs. (72.0 kg)
Weight
FFLLAAMMEE HHEEIIGGHHTT
TTrruuSSeeaarr BBUURRNNEERR
1/4”
(.64 cm)
BBUURRNNEERR AADDJJUUSSTTMMEENNTT
Orifice
There is no burner adjustment for the infrared burner. Once heated, the flames should glow a bright red color.