PLANNING AND DESIGN GUIDE
VIKINGRANGE.COM • 1-888-VIKING1
RELEASED 12/1/07
©2007 VRC—INFORMATION SUBJECT TO CHANGE
OUTDOOR—COOKING
C
4™
Charcoal Ceramic Cooking Capsule
&
C
4™
Cooker Cart
UTILITY
REQUIREMENTS
GAS
(41”W. QSC412 models only)
Not applicable for
QSC200/300 models
Surface burner rating
• Two grated grill burners, each
@ 15,000 BTU (4.4 kW) Nat./
13,500 BTU LP (4.0 kW)
Fixed piping installations*
Check with local gas utility
company or with local codes for
instructions on installing gas
supply lines. All gas connections
should be made by a
competent technician and in
accordance with local codes and
or ordinances. In the absence of
codes, the installation must
comply with the National Fuel
Gas Code ANSI Z223.1.
An installer-supplied gas shut-
off valve must be installed in
an easily accessible location.
All installer-supplied parts
must conform to local codes.
Must be isolated from the gas
supply piping system by
closing its individual manual
shut-off valve during any
pressure testing of that system
at test pressures equal to or
less than 1/2 psi (3.5 kPa).
Natural gas models
Water column pressure
o Operating pressure—4.0”
WCP
o Supply pressure of 6” – 14”
WCP
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 7/8” (2.2 cm) flare
adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the 7/8”
(2.2 cm) male flare on the
regulator assembly.
LP/propane models
Water column pressure
o Operating pressure—10”
WCP
o Supply pressure of 11” – 14”
WCP (for fixed piping
installations)
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
• Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8” (0.95) flare adapter.
LP/propane tank installations
Water column pressure
o Operating pressure—10”
WCP
o Includes high-capacity
hose/regulator assembly for
connection to a standard
5-gal./20-lb. (approx.
12” diameter/18”\H.)
LP/propane gas cylinder
equipped with a Type 1,
QCC-1 connector
The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
cooking appliance.
The cylinder must be
provided with a shut-off
valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified.
The cylinder supply system
must be arranged for vapor
withdrawal and provided with
a listed OPD (overfilling
prevention device).
ELECTRICAL
Not applicable for
QSC200/300 models
9-volt DC battery for
electronic ignition (QSC412
model (side burners))
PLUMBING
Not applicable
Installation Requirements
* For fixed pipe fuel installations, remember to place the installer-supplied gas valve in an accessible location.
Cabinet proximity
The cart can be installed directly adjacent to side cabinets. There is 0” side clearance to non-combustible and combustible surfaces.
Maintain a minimum of 6” (15.2 cm) from the back of the unit to allow cooker dome to open fully.