Uniflame GBC940WIR-C Gas Grill User Manual


 
Contact 1.800.762.1142 for assistance. Do not return to place of purchase.
page no.
11
9. After lighting, observe the burner flame, make sure all burner ports are lit and flame height
matches illustration. (Figure 10)
CAUTION: If burner flame goes out during operation, immediately turn
the gas “OFF” and open lid to let the gas clear for about 5 minutes
before re-lighting.
Turning Off
1. Turn LP gas tank valve to “CLOSED”.
2. Turn control knob clockwise to the “OFF” position.
Note: A “poof” sound is normal as the last of the LP gas is burned.
Cooking
1. Open lid and ignite the burner per lighting instructions in owner’s manual.
2. Adjust controls to desired flame height.
3. Place pan on center of grid.
4. Cook and adjust temperature as needed.
5. Turn grill OFF by turning the LP gas tank valve to “CLOSED”. Burn off remaining gas in lines
by waiting 15 seconds then turn all burner controls to the “OFF” position. A “poof” sound is
normal as the last of the LP gas is burned.
Cleaning and Care
CAUTION:
1. All cleaning and maintenance should be done when grill is cool and
with the fuel supply disconnected.
2. DO NOT clean any grill part in a self cleaning oven. The extreme heat
will damage the finish.
Notices
1. This grill should be thoroughly cleaned and inspected on a regular basis.
2. Abrasive cleaners will damage this product.
3. Never use oven cleaner to clean any part of grill.
4. Do not clean any grill part in a self cleaning oven. The extreme heat will damage the
finish.
Before Each Use:
1. Keep the grill area clean and free from any
combustible materials, gasoline, and other
flammable vapors and liquids.
2. Do not obstruct the flow of the combustion of LP
and the ventilation air.
3. Keep the ventilation opening(s) of the LP gas tank
area free and clear from debris.
4. Visually check the burner flames to make sure your
grill is working properly.
5. See sections below for proper cleaning instructions.
6. Check and clean the burner/venturi tubes for insects
and insect nests. A clogged tube can lead to a fire
beneath the grill.
Cleaning Surfaces
1. Wipe surfaces clean with mild dishwashing
detergent or baking soda mixed with water.
2. For stubborn surfaces use a citrus based degreaser
and a nylon scrubbing brush.
3. Rinse clean with water.
4. Allow to air dry.
Cleaning Main Burner
1. Turn gas “OFF” at the control knobs and LP gas tank
valve to “CLOSED”.
2. Remove cooking grid and heat plates.
3. Remove burner by removing the fasteners securing
the burner to the grill bottom.
4. Lift burner up and away from gas valve orifice.
5. Disconnect wire from spark electrode.
6. Clean inlet (venturi) of burner with small bottle brush or compressed air.
7. Remove all food residue and dirt on burner surface.
8. Clean any clogged ports with a stiff wire (such as an opened paper clip)
9. Inspect burner for any damage (cracks or holes). If damage is found, replace with new
burner.
10. Reinstall burner, check to insure that gas valve orifice is correctly positioned inside burner
inlet (venturi). Also check position of spark electrode.
11. Replace heat plate and cooking grid.
12. Perform leak test.
Operating Instructions
Checking for Leaks
Burner Connections
1. Make sure the regulator valve and hose connections
are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check
the connection between the burner venturi pipe and
orifice. Make sure the burner venturi pipe fits over
the orifice.
WARNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion
which can cause death, serious bodily
injury, or damage to property.
2. Please refer to diagram for proper installation.
(Figure 1 and 2)
3. If the burner pipe does not rest flush to the orifice,
please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part
liquid dishwashing soap with three parts water.
2. Make sure control knobs are “OFF”. (Figure 3)
3. Turn LP gas tank valve to “OPEN”.
4. Spoon leak check solution at all “X” locations
(Figure 4)
a. If any bubbles appear turn LP gas tank valve to
“CLOSED”, reconnect and re-test.
b. If you continue to see bubbles after several
attempts, turn LP gas tank valve to “CLOSED”
and disconnect LP gas tank and contact
1.800.762.1142 for assistance.
c. If no bubbles appear after one minute turn LP gas
tank valve to “CLOSED”, wipe away solution and
proceed.
Operating Main Burners
First Use
1. Make sure all labels, packaging and protective films
have been removed from the grill.
2. Remove manufacturing oils before cooking on this
grill for the first time by operating the grill for at
least 15 minutes on “HIGH” with the lid closed. This
will “heat clean” the internal parts and dissipate
odors.
Lighting
1. Open lid. Attempting to light the burner with the
lid closed may cause an explosion!
2. Make sure there are no obstructions of airflow to
the burners. Spiders and insects can nest within
and clog the burner / venturi tube at the orifice. A
clogged burner tube can lead to a fire beneath the
appliance.
3. All control knobs must be in the “OFF” position.
(Figure 3)
4. Turn LP gas tank valve to “OPEN”.
5. Select burner to light. Push and turn control knob
counterclockwise to “HIGH”.
6. Press the electronic igniter button and hold for 5
seconds to light burner.
7. If ignition does not occur in 5 seconds, turn burner
control knob “OFF”, wait 5 minutes, and repeat
lighting procedure.
8. If igniter does not light burner, use a lit match
secured with the lighting rod provided to light
burners manually. Access the burners through the
cooking grid and heat plates. Position the lit match
near side of the burner. (Figure 5)
Important: Always use the lighting rod provided when
lighting burners with a match.
9. After lighting, observe the burner flame, make sure
all burner ports are lit and flame height matches
illustration. (Figure 6)
Note: Each burner lights independently - repeat steps
5-9 for the other burners.
Operating Sear Burner
First Use
1. Make sure all labels, packaging and protective films have been removed from the grill.
2. Remove manufacturing oils before cooking on this grill for the first time, by operating the grill
for at least 15 minutes on “HIGH” with the lid closed. This will “heat clean” the internal parts
and dissipate odors.
Lighting
NOTE: Infrared sear burner can be used while main
burners are operating.
1. Open lid. Attempting to light the burner with the
lid closed may cause an explosion!
2. Make sure there are no obstructions of airflow to
the gas unit. Spiders and insects can nest within
and clog the burner / venturi tube at the orifice. A
clogged burner tube can lead to a fire beneath the
appliance.
3. Control knob must be in the “OFF” position.
(Figure 7)
4. Turn LP gas tank valve to “OPEN”.
5. Push and turn control knob counterclockwise to “ON”.
6. Press the electronic igniter button and hold for 5 seconds to light burner.
7. Hold the knob 3 to 5 seconds to allow gas to reach and light the burner.
8. Burner should turn red after 2 to 3 minutes.
9. Turn control knob “OFF” if burner is not lit. Wait 5 minutes and repeat lighting procedure.
Caution: If burner flame goes out during operation, immediately turn
the gas “OFF” and open lid to let the gas clear for about 5 minutes
before re-lighting.
Turning Off
1. Turn LP gas tank valve to “CLOSED”.
2. Turn all control knob clockwise to the “OFF” position.
Cooking
Ideal for searing in juices and flavor in food, such as steaks, roasts, and chicken parts.
1. Open lid and ignite the burner per lighting instructions.
2. Close lid and preheat grill on “HIGH”.
3. Wear protective gloves and use long handle tongs to place food onto cooking grids above the
burner.
4. Adjust control to desired temperature.
5. Keep an eye on the food to make sure the food does not burn, as it will take a very short time
to sear each side of the food. Turn as desired.
6. Turn grill OFF by turning the LP gas tank valve
to “CLOSED”. Burn off remaining gas in lines by
waiting 15 seconds then turn all burner controls to
the “OFF” position. A “poof” sound is normal as the
last of the LP gas is burned.
Operating Side Burner
NOTE: Side burner can be used while main burners
are operating.
Never use side burner as a grill.
Lighting
1. Open lid. Attempting to light the burner with the
lid closed may cause an explosion!
2. Make sure there are no obstructions of airflow to the
burner. Spiders and insects can nest within and clog
the burner / venturi tube at the orifice. A clogged
burner tube can lead to a fire beneath the appliance.
3. Control knob must be in the “OFF” position.
(Figure 8)
4. Turn LP gas tank valve to “OPEN”.
5. Push and turn control knob counterclockwise to
“HIGH”.
6. Press the electronic igniter button and hold for 5
seconds to light burner.
7. If ignition does not occur in 5 seconds, turn burner
control knob “OFF”, wait 5 minutes, and repeat
lighting procedure.
8. If igniter does not light burner, use a lit match
secured with the lighting rod provided to light
burners manually. Position the lit match near side of
the burner. (Figure 9)
Important: Always use the lighting rod provided when
lighting burners with a match.
Figure 8
Figure 9
Figure 10
Burner
Flame
Slight
Yellow
Slight
Blue
Dark
Blue
Figure 111
Burner Flame Conditions
Use this chart check to see if your
burners need to be cleaned.
1-2 in. /
25.4 - 50.8 mm
1-2 in. /
25.4 - 50.8 mm
Normal: Soft blue flames with
yellow tips between 1 in. - 2 in.
hight.
Needs Cleaning: Noisy with hard
blue flames.
Has to be cleaned: Wavy with
yellow flames.
Figure 7