10. All Models are equipped with a Tank Gas
Pressure Regulator that is mounted on the LP
tank connector. The regulator is set for LP.
See Figure 6, below.
SECTION 4: UNPACKING, MOVING AND PLACING THE UNIT
9. On all models, the bypass jet must be turned counterclockwise with a small flat-bladed screwdriver
1 to 1
-1
/2 turns to set proper low flow rate. See Figures 4 and 5.
For use with NG, it must be changed. The regulator
is located in the left storage compartment. Remove
and replace with the accessory NATHOSE Kit.
See Figure 6A, below.
FIGURE 6
Tank Gas
Regulator
LP Gas Tank
Gas Hose
FIGURE 6A
2.06