Regency I31-LPG3 Fire Pit User Manual


 
12
Regency I31-3 Gas Fireplace Inbuilt
HAMPTON CAST
FACEPLATE INSTALLATION
1) Lay the faceplate panels flat, face down on something soft so they
don't scratch.
2) Attach the side filler brackets to the left and right sides using 3
screws and washer per side.
3) Attach the right and left cast sides to the top using 2 screws per
side.
5) Connect the ON/OFF switch
wires by taking the black and
red wires with the blue female
ends thru the hole provided
and connecting them to the
ON/OFF switch.
6) Connect the fan switch wires
by taking the black and red
wires with the male ends (in
the grey harness) thru the
hole provided and connect
them with the wire connec-
tors from the fan speed con-
trol.
7) Insert wires into the strain re-
lief and install into switch box
assembly.
Ensure that the top
and sides are
aligned.
4) Use a measuring tape to ensure that the distance between the left
and right side pieces is 28" (711mm).
Switch Box Assembly
Boss on rear left side
piece.
8) Place the switch box assembly over the boss on the rear left side
piece and secure with one screw.
NOTE: Do not install Cast Faceplate when unit is installed into
a Zero Clearance Unit.
28"
9) Tuck the wires into the faceplate to keep
them away from the insert using the clip
provided. Attach the clip to the rear of the
faceplate to ensure that the wires do not
touch the side of the unit.
10) The power cord should be run behind the
faceplate panel.
INSTALLATION
NOTE: There are filler brackets specifically for each side. The
way to differentiate this is that on the side of the brackets
there are 2 mounting holes. The side where there is a 7/16"
gap from the top of the bracket to the mounting hole, must
face the top.